Custom L-Section Copper Contact Blocks

Short Description:

Item Specification
Product Custom L-Section Copper Contact Block / Asymmetric Stepped Copper Terminal
Copper Grade Options C11000, C10200 or C10100; EN and GB grades can be reviewed against the specified material requirements
Applicable Standards ASTM B187/B187M or EN 13605 where applicable to the selected grade and product form; finished components to approved drawings
Profile Geometry Thick main body with a single thin projecting flange
Overall Profile Width 12–260 mm
Thick Block Height 8–120 mm
Thin Flange Thickness 1.5–30 mm
Supply Length Cut blocks: 10–800 mm; straight profile bars: 1000–6000 mm
Material Condition Soft or hard condition, as specified under the applicable material standard
Supply Forms Profile bar, cut blank, rough-machined block or finish-machined component
Custom Machining Drilled holes, tapped holes, slots, chamfers, corner relief and functional surfaces
Surface Options Bare copper, anti-tarnish treatment or optional silver, tin or nickel plating
Tolerance According to the approved drawing and manufacturing feasibility review
Inspection Material verification, dimensions, flange thickness, step geometry, flatness and surface condition; conductivity and ultrasonic testing as specified
Documentation Material certificates, dimensional reports and agreed process or coating records

Product Detail

Product Tags

Video

Product Overview

An L-section copper contact block is an asymmetric conductive component with a thick main body and a thin flange extending from one side. This geometry provides separate areas for electrical contact, mounting or connection to another conductor.

Cymber Metal supports material selection from itspure copper range, together with profile forming, cutting and secondary machining. The final section, material condition and finishing route are selected according to the component drawing and application requirements.

Key Features

  • Asymmetric L-section:Combines a substantial main body with a thinner connection or mounting flange.
  • Custom material selection:ETP or oxygen-free copper options according to electrical, thermal and processing requirements.
  • Flexible supply forms:Long profiles, cut blanks and finished components for different production workflows.
  • Drawing-based finishing:Optional machining and plating for the specified contact and assembly interfaces.

Manufacturing & Quality Control

The production route may combinecustom copper profile extrusionwith cold drawing, straightening and machining. Not every component requires every operation.

Stage Process / Control
Drawing Review Confirm section geometry, flange projection, corner radii, datums and critical dimensions
Material Selection Confirm copper grade, condition and required material documentation
Profile Forming Select extrusion, cold drawing or a machining-based route according to geometry and quantity
Cutting & Straightening Establish the specified supply length and control straightness and flatness
Secondary Machining Produce holes, threads, slots and functional surfaces where required
Surface Treatment Apply the agreed cleaning, protection or plating specification
Final Inspection Verify drawing requirements and prepare the agreed inspection records

Additional features can be reviewed through ourprecision machining support. Inspection scope and documentation are agreed before production; see ourquality assurance approachfor further information.

Typical Applications

Application Potential Component Function
ACB and MCCB Assemblies Stationary-contact seats and conductive connection blocks
Industrial DC Contactors Conductive blocks and connection interfaces
Rectifiers and Energy Storage PCS Thick-to-thin busbar transition terminals
Resistance Welding Equipment Conductive holders and connection blocks, subject to material and duty-cycle review

Application suitability depends on the complete assembly, including contact design, fastening, cooling and operating conditions.

FAQ

What is an L-section copper contact block?

It is a copper component with a thick body and a thinner flange extending from one side. The stepped geometry allows the main body and flange to serve different contact, connection or mounting functions.

How does an L-section differ from a T-section copper profile?

An L-section has a flange projecting from one side of the main body. A T-section extends on both sides of a central section. The appropriate shape depends on the available space and connection arrangement.

Which copper grades can be specified?

Options include C11000 electrolytic tough-pitch copper and oxygen-free grades such as C10200 or C10100. Selection depends on the applicable standard, conductivity requirements and subsequent processing. EN and GB grades should be specified individually rather than assumed to be exact equivalents.

Can you supply both profile bars and finished blocks?

Yes. Supply options include straight profile bars, cut-to-length blanks and machined components. The preferred option depends on order quantity, required features and whether the customer will carry out further machining.

Can the thin flange be drilled or tapped?

Holes, slots and threads can be reviewed against the drawing. Thread feasibility depends on flange thickness, hole location, engagement length and assembly loads. A thin flange may require a clearance hole and separate fastening arrangement instead.

What tolerances are available?

Tolerances are confirmed by drawing review. Overall profile dimensions, flange thickness, flatness, perpendicularity and machined features may require different controls. Please identify critical datums and functional dimensions when requesting a quotation.

Can the copper blocks be silver-, tin- or nickel-plated?

These finishes can be reviewed according to the application. Please specify the coating material, thickness, coverage, masking areas and acceptance requirements. Selective plating may be appropriate where only particular contact surfaces require treatment.

Does the copper block have a fixed current rating?

No universal current rating applies to this geometry. Allowable current depends on conductor dimensions, contact resistance, joint design, cooling and temperature-rise limits. Switching and short-circuit performance must be validated in the intended equipment assembly.

Request a Quote

Contact Cymber Metalwith your drawing, copper grade, material standard, profile dimensions, flange thickness, cut length, tolerances and quantity. Please also include surface treatment, operating conditions, inspection documents, delivery destination and required schedule so we can review the appropriate production route.