Dual-Bent Copper Contact Finger Strip

Short Description:

Item Reference Specification
Product Type Dual-bent copper contact finger strip
Main Material Options C11000, C10200 or C10100 copper
Other Grade Options Cu-ETP, Cu-OF, TU1 or TU2, subject to standard and grade confirmation
Overall Length 35–350 mm
Strip Width 6–60 mm
Strip Thickness 2–12 mm
Central Mounting Section Flat body with two drawing-defined mounting holes
Front Contact Geometry Lead-in ramp or angled contact end
Rear Contact Geometry Stepped relief, returned bend or retaining hook according to drawing
Front Bend Angle Reference range: 120°–165°
Rear Bend Angle Nominal 90° where a hook or returned end is required
Width / Thickness Tolerance Reference requirement: ±0.02 mm
Dual-End Bend Angle Tolerance Reference requirement: ±0.3°
Contact Ridge Height Reference requirement: ≤0.015 mm where a formed ridge is specified
Contact-Zone Roughness Reference requirement: Ra 0.2–0.4 µm
Hardness Reference range: 95–135 HV for a specified hard temper
Mounting Holes Through-holes, countersunk holes or other details according to drawing
Surface Options Bare copper, anti-tarnish treatment, silver plating, tin plating or nickel plating
Optional Silver Thickness Reference range: 10–30 µm
Conductivity Grade-specific value to be confirmed by material certificate and test method
Applicable Material References ASTM B187, ASTM B152, ASTM B133, EN 13601, EN 13605, JIS H3140 or GB/T 5585 where applicable
Supply Basis Approved drawing, confirmed material condition and agreed inspection plan

Product Detail

Product Tags

Video

Short Description

This dual-bent copper contact finger strip is a formed conductive component for drawing-defined switchgear and electrical assemblies. The photographed design has a long flat body, two mounting holes and bent contact ends at opposite sides.

Material grade, temper, bend angles, contact profile, hole geometry and surface treatment can be customized. C11000, C10200 and C10100 copper options can be reviewed according to conductivity, forming requirements and order documentation.

Product Overview

A copper contact finger strip is used as an individual conductive element within a larger contact assembly. Several fingers may be arranged in parallel or in a circular cluster, depending on the equipment design.

The supplied photos show a narrow copper strip with two mounting holes in the central flat section. One end forms an angled lead-in section, while the opposite end includes a raised or returned retaining feature. The exact contact ridge, bend radii, hook dimensions and hole style should be confirmed from the production drawing.

The dual-bent shape can help package the contact interface and mounting section within a limited installation space. It should not be treated as a guaranteed spring rate, contact force or fatigue-performance specification without engineering calculations and testing.

The product can be considered for disconnectors, earthing switches, switchgear plug-in interfaces, vacuum circuit breaker assemblies, transformer tap-changer components and other custom electrical equipment.

For material selection, see Cymber Metal’spure copper products. For forming, drilling, countersinking and drawing-based finishing, ourfine machining servicecan be reviewed.

Contact resistance, current capacity, temperature rise and mechanical endurance depend on the complete finger assembly, mating contact, clamping method, operating cycle and equipment design.

Key Features

Feature Design Detail / Buyer Benefit
Dual-Bent Geometry Places the contact ends and mounting section at different orientations for compact assembly integration.
Long Flat Mounting Body Provides a defined area for the two visible mounting holes and installation hardware.
Lead-In End A drawing-defined angled end can guide the mating contact during assembly or operation.
Returned End / Retaining Feature The opposite bend can be designed to locate within a slot or support a mechanical retention function.
Optional Contact Ridge A formed or machined ridge can be specified where the mating contact requires a defined line or raised contact area.
Formed Copper Construction Reduces the need for multiple joined pieces when the design is produced from one strip blank. Final construction depends on the approved process.
Custom Hole Pattern Hole diameter, spacing, countersink and edge distance can be adapted to the mounting assembly.
Finish Options Bare copper or plated contact areas can be selected according to electrical, wear and environmental requirements.
Assembly-Based Design The strip can be engineered around the mating contact, required insertion path, mounting space and operating cycle.

Manufacturing Process

A typical route uses copper strip preparation, controlled forming and secondary hole finishing. The final process depends on the grade, thickness, bend geometry and order quantity.

Stage Process Main Control Points
Drawing Review Review the 2D drawing, 3D model and mating contact information. Strip length, width, thickness, hole pattern, bend sequence and datums
Material Preparation Select copper strip in the specified grade and condition. Grade, temper, thickness, surface condition and certificate requirements
Blank Cutting Cut or blank the strip to the required outline. Length, width, edge condition and burr control
Progressive Forming Form the front and rear bends with suitable dies and springback compensation. Bend angles, bend radii, flatness and end alignment
Contact Feature Forming Coin or machine any specified ridge, ramp or locating feature. Ridge height, contour, straightness and surface condition
Hole Machining Drill, punch, countersink or finish the two mounting holes. Hole diameter, center distance, countersink angle and position
Deburring Remove loose burrs from edges and holes. Edge radius, cleanliness and contact-surface protection
Surface Treatment Apply anti-tarnish treatment or specified plating after forming. Plated area, coating thickness, masking and adhesion
Final Inspection Inspect the finished finger against the approved drawing. Dimensions, bend angles, hole locations, finish and documentation

For plated contact areas, Cymber Metal’sbusbar plating shopprovides relevant process context. Plating thickness, selective areas and masking requirements should be agreed before production.

Manufacturing & Quality Control

The inspection scope should be defined according to the component’s role in the complete contact assembly.

Inspection Item Method / Control Approach Acceptance Basis
Material Identification Review material certificates and arrange composition testing when required. Ordered copper grade and applicable standard
Conductivity Use an agreed conductivity or resistivity test method with calibrated equipment. Grade-specific electrical requirement
Strip Dimensions Measure length, width and thickness at agreed locations. Approved drawing tolerances
Bend Geometry Check both bend angles, radii, end alignment and springback. Drawing-defined geometry and tolerance
Contact Profile Inspect the lead-in ramp, ridge, hook or returned end. Approved profile and mating-contact requirements
Mounting Holes Check diameter, center distance, edge distance, countersink and burrs. Mounting interface drawing
Surface Roughness Measure designated contact zones with a profilometer. Specified Ra value
Hardness Perform Vickers hardness testing at agreed locations. Material temper and order specification
Plating Check coating thickness, coverage, adhesion and appearance where applicable. Agreed plating specification
Visual Inspection Check for cracks, folds, scratches, dents, excessive burrs and contamination. Approved visual acceptance criteria
Assembly Simulation Use a fixture or mating component to check fit when required. Customer assembly requirements
Documentation Provide material, dimensional, plating and inspection reports as agreed. Purchase order and inspection plan
Qualification Testing Arrange contact-resistance, temperature-rise, insertion-cycle or equipment-level tests when specified. Complete assembly qualification plan

See Cymber Metal’sQuality Assurancepage for additional quality and inspection context. Product certificates and third-party reports should be confirmed for the actual order.

Typical Applications

The following are potential uses for engineering review and are not guaranteed ratings for the component.

Application Potential Component Role Points to Confirm
Medium-Voltage Switchgear Individual spring contact finger in a fixed or plug-in contact assembly Mating profile, contact force, current and temperature rise
Ring Main Units Formed contact segment within a compact switching interface Space constraints, insulation clearance and operating travel
Disconnectors Elastic or fixed contact element for a moving blade interface Mechanical endurance, alignment and contact resistance
Earthing Switches Conductive finger in the grounding contact path Fault-current duty, grounding continuity and mechanical forces
Vacuum Circuit Breakers Contact finger or bridge element around a primary isolation plug Plug-in geometry, insertion force and wear
Air Circuit Breakers Contact segment for a primary circuit connection Breaker manufacturer interface and thermal requirements
Transformer Tap Changers Flexible or formed contact segment in a switching mechanism Cycle life, oil environment, wear and contact pressure
Energy Storage Equipment Compact copper contact in a quick-change or serviceable power module DC current, vibration, insulation and thermal cycling

Frequently Asked Questions

What is a copper contact finger strip?

A copper contact finger strip is a formed conductive strip used as one element of a larger electrical contact assembly. Its shape may include bends, mounting holes, lead-in surfaces, ridges or retaining features that match the equipment’s mating contact.

Is this component a flexible connector?

Not automatically. The part is a formed copper strip, but its permitted movement and spring behavior depend on thickness, material condition, bend geometry and mounting. It should not be specified as a flexible connector without mechanical analysis and qualification testing.

Which copper grades can be used?

C11000, C10200 and C10100 can be considered. The correct grade depends on conductivity, forming behavior, hardness, operating temperature and documentation requirements. Final material selection should follow the customer’s standard and drawing.

Can the two mounting holes be customized?

Yes. Hole diameter, spacing, countersink, edge distance and positional tolerance can be customized. The photos show two holes, but the exact hole form and dimensions must be confirmed from the production drawing.

Can both bent ends be changed?

Yes. The front lead-in angle, rear returned angle, bend radii, hook dimensions and end lengths can be adjusted to match the mating assembly. Tolerance feasibility depends on strip thickness, material temper and forming method.

Can the contact area be silver-plated?

Selective silver plating can be reviewed for designated contact areas. The order should specify plating thickness, plated zones, masking, adhesion requirements and inspection method. Plating does not by itself guarantee a specific assembled contact resistance.

Is this finger suitable for high-voltage switchgear?

It may be considered for suitable switchgear after engineering review. Voltage rating, current, temperature rise, insulation coordination, short-circuit forces and mechanical endurance belong to the complete qualified assembly, not the part alone.

What information is needed for a quotation?

Please provide the drawing or 3D model, copper grade, strip dimensions, bend angles, hole details, mating contact, surface treatment, quantity, inspection documents and destination. These details allow the forming route and acceptance criteria to be reviewed accurately.

Request a Quote

Required Information Details to Include
Drawing / 3D Model Dimensioned PDF drawing and STEP or equivalent model
Material Copper grade, standard and temper
Strip Dimensions Length, width, thickness and blank outline
Bend Details Front angle, rear angle, bend radii, hook or returned-end geometry
Contact Features Lead-in ramp, ridge, contact length and mating profile
Mounting Holes Diameter, spacing, countersink, edge distance and position tolerance
Surface Treatment Bare copper, anti-tarnish, silver, tin or nickel plating
Operating Conditions Current, frequency, temperature, environment and operating cycle
Quantity Prototype, batch quantity and estimated annual demand
Inspection Documents Material certificate, dimensional report, plating report or third-party inspection
Delivery Details Destination, packaging and required schedule

Contact Cymber Metal for a drawing-based quotation. Please send the drawing and mating-interface information so material, forming, hole finishing, surface treatment and inspection can be reviewed together.


  • Previous:
  • Next:

  • Write your message here and send it to us