Custom 90-Degree L-Bent Copper Busbar Transition Bracket
Video
Short Description
Cymber Metal supplies custom L-bent copper transition brackets with a central-bored flange at one end and a separate mounting-hole pattern at the other. The pictured component has a formed right-angle section; the hole layout, dimensions and material specification should be confirmed against the approved drawing.
The component can be reviewed for switchgear and other electrical connection designs. Current rating, temperature rise and suitability depend on the complete assembly, material specification, contact interfaces and operating conditions.
Product Overview
This L-shaped copper terminal connects two mounting interfaces set at an angle. The visible design combines a larger central bore with surrounding holes at one end and a rounded four-hole connection end at the other. Hole sizes, spacing, bend geometry and mating dimensions are specified by drawing.
For material options, see ourPure Copperpage. Custom machining and drawing review can be discussed through ourFine Machiningcapability.
Key Features
| Feature | Description |
|---|---|
| Right-angle form | Connects two interfaces arranged at an angle; final bend geometry is drawing-defined. |
| Dual-end hole patterns | Combines a central-bored end with surrounding holes and a four-hole connection end. |
| Rounded connection end | The visible four-hole end has a rounded outer profile. |
| Custom interface geometry | Hole positions, bore size, edge details and mating faces can be specified by drawing. |
| Copper construction | The copper grade and material condition should be selected according to the application requirements. |
Manufacturing Process
| Stage | Scope |
|---|---|
| Drawing Review | Confirm material, bend geometry, hole patterns, critical dimensions and mating interfaces. |
| Material Preparation | Prepare copper stock to the agreed specification and component dimensions. |
| Blanking or Cutting | Produce the required blank and outer profile using a process selected for the drawing. |
| Forming | Make the right-angle bend using a method suited to the specified material condition and bend radius. |
| Hole and Bore Machining | Produce the central bore and mounting holes to the approved drawing. |
| Finishing | Deburr and clean; apply plating only if it is part of the order specification. |
| Final Inspection | Check agreed critical dimensions, hole locations, formed geometry and surface condition. |
Manufacturing & Quality Control
| Control Stage | Review or Inspection |
|---|---|
| Drawing and Feasibility Review | Review material, dimensions, interfaces, bend radius and critical tolerances before production. |
| Material Verification | Confirm the grade and supporting material records according to the purchase specification. |
| Dimensional Inspection | Check agreed features such as bore size, hole positions, mounting faces and formed dimensions. |
| Formed-Feature Inspection | Review the bend and component condition against the drawing requirements. |
| Surface and Edge Inspection | Check for burrs and visible surface conditions against the agreed acceptance criteria. |
| Plating Inspection | If plating is ordered, confirm coating coverage and inspection requirements separately. |
| Documentation | Material certificates, dimensional reports and additional test records are subject to order agreement. |
For inspection methods and available documentation, see ourQuality Assurancepage. Product-specific inspection scope and acceptance criteria should be agreed before order placement.
Typical Applications
| Potential Application | Possible Use | Design Checks |
|---|---|---|
| Switchgear busbar connections | Right-angle transition between mounting interfaces | Equipment layout, mating faces, current duty and thermal limits |
| Bushing-to-busbar connections | Adapter between a bushing interface and a busbar connection | Bushing dimensions, hole pattern, clearances and equipment design |
| Circuit breaker connections | Custom terminal for a specified breaker assembly | OEM drawing, contact interface and electrical rating |
| Distribution equipment | Formed connector in a custom panel or busbar assembly | Installation envelope, fastening method and operating conditions |
These are potential application contexts, not equipment approvals or confirmed ratings. The equipment designer should verify suitability for the complete assembly.
FAQ
It is a formed copper connection component with two mounting interfaces arranged at an angle. This pictured design has a central-bored end with surrounding holes and a separate four-hole end.
Yes. Bore diameter, hole count, hole size, spacing and edge treatment can be reviewed against your drawing and mating requirements.
Please provide the required grade and standard if known. C11000 or C10200 may be considered for suitable designs, but the final selection depends on the electrical, forming and operating requirements.
They can be reviewed as drawing-defined features. Feasibility depends on stock thickness, material condition, bend radius and the finished dimensions.
It may be considered for a specific breaker or GIS connection design, but the photograph alone does not establish compatibility. The OEM interface, clearances and equipment requirements need to be checked.
Plating can be discussed if required. Specify the coating type, areas, thickness and acceptance requirements; plating is not confirmed by the photographs.
Material and dimensional records can be discussed according to the purchase specification. Any additional tests or reporting requirements should be agreed before production.
Please send the 2D or 3D drawing, material grade and condition, quantity, critical tolerances, finish or plating requirements, application and destination.
Request a Quote
| Please Provide | Details |
|---|---|
| Drawing | 2D or 3D file showing both hole patterns, bore, bend and overall dimensions |
| Material | Grade, standard and required condition |
| Quantity | Sample, prototype and production quantities, if applicable |
| Critical Requirements | Tolerances, mating interfaces and electrical or thermal criteria |
| Surface Treatment | Bare copper or specified plating and finish |
| Inspection and Documents | Required inspection scope and material records |
| Delivery | Destination country and target schedule |
Send your drawing and requirements throughContact Usfor a material and manufacturing review.