L-Bent Slotted Copper Busbar Connector
Video
Short Description
Cymber Metal supplies custom L-bent slotted copper busbar connectors for drawing-defined electrical connections. The photographed design features four longitudinal through-slots forming five ribs across the bend, a rounded flat mounting end, and a split upright mounting end.
Material grade, arm dimensions, bend radius, slot geometry, mounting holes and surface treatment can be specified for the application. C11000, C10200 and C10100 copper options can be reviewed according to conductivity, forming and documentation requirements.
Product Overview
An L-bent slotted copper busbar connector provides an angled conductive connection between mounting interfaces. Its geometry combines a bent copper body with longitudinal openings and drilled terminal pads.
The illustrated component has four long slots extending across the curved section, dividing that region into five ribs connected at both ends. One mounting end has a rounded outline and two holes. The opposite end includes two mounting holes separated by a central end slit.
This configuration can be evaluated for switchgear, power conversion equipment, transformer connections and other custom busbar assemblies. Slot dimensions, remaining copper cross-section, joint contact area and mechanical loading must be considered together when developing the design.
Material selection can start with Cymber Metal’spure copper materials. Drawing-defined slots, mounting interfaces and finishing requirements can be reviewed through ourcopper machining support.
Current capacity, temperature rise and electrical withstand performance depend on the complete installed assembly. These characteristics cannot be established from the component’s appearance alone.
Key Features
| Feature | Design Detail / Buyer Benefit |
|---|---|
| L-Bent Geometry | Provides an angled connection between two mounting interfaces. Arm lengths, bend radius and interface orientation can be drawing-defined. |
| Four-Slot, Five-Rib Layout | Divides the bent section into parallel ribs while retaining connected terminal regions at both ends. |
| Openings Across the Bend | Creates open passages through the curved region. Any cooling benefit depends on enclosure conditions, airflow and thermal validation. |
| Split Mounting End | Includes a central slit between the two end mounting areas. Its effect on seating and deformation depends on geometry and bolt loading. |
| Two-Hole Mounting Interfaces | Supports drawing-defined bolted connections at both ends. Hole geometry and spacing must match the mating assembly. |
| Rounded External Outline | Provides a rounded terminal outline and edge transitions; specified edge radii can be included in the drawing. |
| Defined Contact Surfaces | Contact pad flatness, roughness and coating can be controlled separately from non-contact surfaces. |
| Material and Finish Options | Allows material condition and surface treatment to be selected for the electrical, mechanical and environmental requirements. |
Manufacturing Process
A practical manufacturing route for this geometry is to form the copper blank before machining the long slots. The final sequence, tooling and machining method should be confirmed during drawing review.
| Stage | Process | Main Control Points |
|---|---|---|
| Drawing Review | Review the 2D drawing, 3D model and mating interfaces. | Material grade, arm dimensions, bend radius, slot geometry, datums and contact areas |
| Material Preparation | Select and cut suitable copper stock. | Material identification, thickness, condition and machining allowance |
| Controlled Bending | Form the blank using suitable tooling and a defined bend radius. | Bend angle, local thinning, distortion and visible surface defects |
| Slot Machining | Machine the longitudinal slots using suitable CNC equipment and workholding. | Slot width, rib thickness, spacing, tool access and support of the bent section |
| Terminal Machining | Finish mounting pads, holes, end slit and other drawing-defined details. | Hole position, pad geometry, contact-face condition and datum relationships |
| Edge Finishing | Remove burrs and finish specified edges. | Slot ends, hole edges, external radii and cleanliness |
| Surface Treatment | Apply the agreed cleaning, anti-tarnish treatment or plating. | Surface preparation, coating coverage, masking and dimensional allowance |
| Final Inspection | Inspect the finished component against agreed requirements. | Dimensions, finish, material records and order-specific acceptance criteria |
For coating-related requirements, Cymber Metal’sbusbar plating shopprovides relevant service context. Coating type, thickness, adhesion requirements and masked areas should be specified before production.
Manufacturing & Quality Control
Inspection scope, sampling frequency and documentation should be agreed before production. The following items provide a basis for an order-specific quality plan.
| Inspection Item | Method / Control Approach | Acceptance Basis |
|---|---|---|
| Material Identification | Review material certificates and arrange composition testing where required. Oxygen-related requirements need an appropriate verification method. | Ordered grade, material standard and certificate requirements |
| Electrical Conductivity | Use an agreed conductivity or resistivity test method with suitable calibration and temperature control. | Specified minimum value for the selected grade and finished condition |
| Overall Geometry | Check arm dimensions, bend angle and mounting interface orientation. | Approved drawing and agreed datum system |
| Slot and Rib Geometry | Measure slot width, rib thickness, spacing and relevant feature relationships. | Drawing-defined dimensions and tolerances |
| Mounting Holes | Check hole dimensions, position, spacing and any specified counterbores or elongated features. | Mating-interface requirements |
| Contact Pad Condition | Check flatness, surface roughness and surface cleanliness. | Specified contact area and inspection method |
| Bend Integrity | Conduct visual inspection; arrange additional surface or volumetric testing when specified and technically appropriate. | Agreed defect limits and inspection procedure |
| Hardness | Test at agreed locations where hardness is an acceptance requirement. | Material condition and drawing requirement |
| Plating Quality | Check coating thickness, coverage, adhesion or other characteristics as specified. | Agreed coating specification and test plan |
| Documentation | Arrange material records, dimensional reports and applicable additional certificates. | Purchase order requirements; EN 10204 3.1 documentation where applicable and agreed |
| Assembly Performance | Define any required joint-resistance, temperature-rise, dielectric or short-circuit testing at the appropriate assembly level. | Applicable equipment standard and customer qualification plan |
For further inspection and documentation information, see Cymber Metal’sQuality Assurancepage.
Typical Applications
These are potential application areas for drawing-based evaluation, not prequalified equipment ratings.
| Application | Potential Component Role | Engineering Points to Confirm |
|---|---|---|
| Switchgear Busbar Assemblies | Angled connection between busbars, terminals or conductive interfaces | Current, temperature rise, clearances, contact area and short-circuit forces |
| Air Circuit Breaker Connections | Custom connection between a breaker terminal and the external busbar arrangement | Mounting geometry, bolt loading and manufacturer-specific requirements |
| Converter and Inverter Equipment | Angled conductive transition within a power conversion assembly | AC/DC duty, frequency content, current distribution and enclosure cooling |
| Energy Storage Power Conversion Systems | Custom busbar connection between equipment interfaces | Continuous current, thermal cycling, insulation and installation access |
| Transformer and Traction Equipment | Drawing-defined terminal transition or busbar bracket | Mechanical support, vibration, joint integrity and thermal loading |
| Induction Heating Power Supplies | Custom copper connection for a frequency-specific circuit design | Skin and proximity effects, net cross-section and validated AC losses |
Frequently Asked Questions
An L-bent slotted copper busbar connector is a copper conductive component with angled mounting interfaces and slots through part of its body. The illustrated version has four longitudinal slots forming five ribs across the bend. It is a custom connection component, not a complete switch or circuit breaker.
Not necessarily. A slotted solid copper body should not automatically be treated as equivalent to a braided or laminated flexible connector. Any permitted movement, spring response, vibration accommodation or fatigue life must be established from the material, geometry, mounting conditions and testing.
Not automatically. Slots change the available copper cross-section, exposed surface area and current paths. Depending on frequency and installation conditions, they may also affect AC losses and airflow. Improved ampacity or reduced losses must be demonstrated through suitable calculation, simulation or testing.
C11000 is a common option for electrical copper components. C10200 or C10100 may be specified where oxygen-free material is required. Selection should consider conductivity, forming, temperature and certification needs. Alternative alloys require separate review because their electrical and mechanical properties differ from pure copper.
Yes, these features can be reviewed against customer drawings. Please specify hole dimensions, elongated-hole or counterbore details, center distances, end-slit geometry, bend angle and mating interfaces. Critical tolerances should reference a clear datum system so manufacturing and inspection use the same basis.
No. The listed figures are references for quotation and feasibility review. Achievable tolerances depend on part size, copper condition, bend geometry, machining access and inspection method. Final acceptance requirements must be confirmed on the approved drawing and purchase order.
These finishes can be reviewed according to the application. Specify the coating material, thickness, plated contact areas, masking and relevant test requirements. Finish selection should consider mating materials, temperature and environment. Plating alone does not establish the assembled joint’s resistance or service life.
A standalone connector should not be described as certified to these equipment standards without supporting evidence. Relevant requirements may form part of the complete assembly’s qualification. Specify the equipment type, applicable standard and required test evidence so the component’s role can be evaluated correctly.
Request a Quote
To request a quotation for a custom L-bent copper connector, please provide the following information.
| Required Information | Details to Include |
|---|---|
| Drawing / Model | Dimensioned PDF drawing and STEP or another agreed 3D format |
| Material | Copper grade, material standard and required condition |
| Main Dimensions | Arm lengths, width, thickness, bend radius and bend angle |
| Slots and Ribs | Slot count, width, length, end radius, spacing and minimum rib thickness |
| Mounting Interfaces | Hole dimensions, hole positions, end slit, contact areas and mating details |
| Critical Tolerances | Datum system, hole position, flatness, angular tolerance and surface roughness |
| Electrical Conditions | AC/DC, operating current, frequency, temperature limits and relevant assembly requirements |
| Surface Treatment | Bare copper or specified plating, thickness and masking |
| Quantity | Prototype quantity, batch quantity and estimated annual demand |
| Inspection Documents | Material certificate, dimensional report, coating report or third-party inspection requirements |
| Delivery Requirements | Destination, packaging needs and requested delivery schedule |
Contact Cymber Metal for a drawing-based quotation. Send your drawings and operating requirements so we can review material selection, processing feasibility, inspection scope and surface treatment.