Curved-Tip Copper Contact Blade with Countersunk Holes
Video
Short Description
Cymber Metal supplies custom copper contact blades with an upturned lead-in tip, rounded edges and countersunk mounting holes. The photographed version features four conical countersinks on one face and a single curved end. Compatible countersunk screws can be seated flush with or below the specified face, subject to fastener and hole geometry. Material options include C11000 ETP copper, C10200 oxygen-free copper and C10100 oxygen-free electronic copper. Dimensions, tip profile, hole pattern and optional contact finishes are tailored to customer drawings for switchgear and other engineered electrical contact assemblies.
Copper Contact Blade Overview
A copper contact blade is a conductive bar or strip used as part of an electrical contact assembly. This curved-tip version combines a longitudinal contact face with an upturned entry end and recessed mounting features.
The photographed component has four countersunk holes, rounded long edges and a curved tip at one end. Its opposite face shows the corresponding through-holes without the large conical recesses.
The upturned end provides a lead-in geometry that can be matched to a moving contact or mating assembly. Countersunk mounting allows suitable screw heads to sit at or below an agreed surface level. Together, these features can support compact installation where projecting fasteners would interfere with nearby components.
Sliding performance still depends on the complete contact system. Contact pressure, alignment, mating material, coating, lubrication where permitted, and the location of mounting interruptions must be reviewed together.
Cymber Metal supports drawing-based selection from itspure copper material range. Where an oxygen-free grade is required,C10200 copperis one option for technical review.
Key Features
| Feature | Practical Value |
|---|---|
| Curved Lead-In Tip | Provides an entry profile that can be matched to the mating contact geometry |
| Countersunk Mounting Holes | Allows compatible screws to sit flush with or below a specified surface level |
| Four-Hole Sample Configuration | Provides multiple fixing locations; spacing and quantity can be customized |
| Rounded Longitudinal Edges | Reduces sharp-edge handling risks and supports controlled edge geometry |
| Drawing-Specific Contact Face | Allows contact zones, surface finish and mounting interruptions to be defined together |
| Copper Grade Options | Supports selection according to conductivity, processing and service requirements |
| Optional Contact Plating | Allows surface properties to be matched to the mating material and contact duty |
| Custom Tip and Hole Geometry | Accommodates equipment-specific mounting and engagement requirements |
Rounded edges do not eliminate electrical discharge, and multiple screws do not establish a short-circuit withstand rating. These aspects require assembly-level engineering and verification.
Manufacturing & Quality Control
Manufacturing is planned around the required contact geometry, screw seating, material condition and final surface finish.
Manufacturing Process
| Stage | Process and Control Focus |
|---|---|
| Drawing Review | Confirm contact zones, mounting datums, tip geometry, screw specification and required fastener clearance |
| Material and Temper Selection | Select suitable copper stock and condition against conductivity, forming and mechanical requirements |
| Blank Preparation | Cut suitable flat bar or strip; rounded-edge drawn stock may be considered where appropriate |
| Tip Forming | Form the curved end using a suitable radius and material condition; review springback and local deformation |
| Drilling and Countersinking | Produce the hole pattern and conical seats with controlled location, angle and depth |
| Double-Side Deburring | Remove entry and exit burrs without changing the specified screw seats or supporting face |
| Contact-Face Finishing | Finish designated contact areas to the agreed roughness and geometry |
| Optional Plating | Apply the specified finish, allowing for coating thickness at screw seats and contact interfaces |
| Protection and Packing | Protect contact surfaces and separate parts to reduce scratching during handling and shipment |
Hole patterns, countersinks and selected contact faces can be reviewed through ourcustom copper machining services. Optional finishing routes are introduced on ourbusbar plating page.
Quality Control and Inspection
| Inspection Item | Method and Acceptance Basis |
|---|---|
| Material Identity | Review material documents and use grade-appropriate composition verification where required |
| Oxygen-Free Requirements | Confirm oxygen-related requirements using appropriate certificates or dedicated testing, rather than routine composition screening alone |
| Electrical Conductivity | Use an agreed method with suitable calibration, temperature control and allowance for part geometry |
| Hardness | Test at agreed locations where hardness is specified; account for changes associated with forming |
| Overall Dimensions | Inspect length, width, thickness and mounting references against the drawing |
| Hole Pattern | Check diameter, location, pitch and alignment to the agreed datums |
| Countersink Geometry | Inspect included angle, major diameter and depth against the nominated screw geometry |
| Screw-Head Seating | Check actual nominated screws for head projection or recess, including relevant fastener and coating tolerances |
| Curved Tip | Inspect tip rise, angle, transition radius and alignment |
| Contact and Supporting Faces | Check specified straightness, flatness and roughness over defined evaluation areas |
| Surface Condition | Inspect holes, edges and formed regions for unacceptable burrs, cracks or damage |
| Coating | Verify specified thickness, coverage and order-specific coating requirements |
| Functional Validation | Agree mating-contact, wear or electrical tests where required; these are separate from dimensional inspection |
| Documentation | Define material records, traceability, dimensional reports and any third-party inspection before production |
Inspection scope and sampling frequency are agreed for each order. EN 10204 3.1 documentation, where required and applicable, must be confirmed before ordering.
Visit ourquality assurance pagefor further information on inspection and quality management.
Typical Applications
The following are potential applications for drawing-specific versions. Suitability must be established by the equipment manufacturer.
| Application | Typical Use | Design Considerations |
|---|---|---|
| Switchgear Contact Assemblies | Conductive contact bars with recessed mounting | Contact pressure, mating geometry, temperature rise and insulation coordination |
| Disconnectors and Earthing Switches | Blade or contact-strip components with shaped entry ends | Engagement path, alignment, operating force and contact resistance |
| Circuit-Breaker Assemblies | OEM-specified conductive bars or stationary contact components | Electrical duty, mounting strength, heat rise and equipment-level testing |
| Sliding or Plug-In Contacts | Contact strips with controlled lead-in geometry | Wear, surface finish, plating, contact continuity and mounting-hole interruptions |
| Transformer Tap-Changer Mechanisms | Drawing-specific contact-track components | Switching medium, erosion, contact force and OEM qualification |
| Specialized Arc-Management Assemblies | Arc-runner geometry manufactured to a validated OEM design | Arc transfer, erosion, material selection and complete interruption testing |
A curved copper tip alone does not establish arc-running, arc-extinguishing or breaking capacity. Those functions depend on the complete device.
Frequently Asked Questions
It is a drawing-specific conductive component for electrical contact assemblies. The curved end provides a shaped entry profile, while countersunk holes accommodate recessed mounting screws. Whether it serves as a stationary contact, blade or contact track depends on the equipment design.
The tip provides a gradual entry geometry that can be matched to a moving contact or mating component. Its effect on engagement force and wear depends on tip angle, radius, alignment, contact pressure and surface finish. These factors should be verified together.
They can when screw-head dimensions, countersink angle, diameter and depth are correctly matched. Coating thickness and fastener tolerances also matter. Final seating should be checked with nominated screws; countersinking alone does not guarantee a completely unobstructed sliding path.
A drawing-specific version may form part of an OEM-designed arc-management assembly. However, the photographed shape does not demonstrate arc-transfer or interruption performance. Arc-runner suitability requires review of the complete device, operating duty, material and relevant test results.
C11000 is ETP copper, while C10200 and C10100 are oxygen-free grades with different specification requirements. Selection depends on conductivity, forming, thermal conditions and documentation needs. Silver-bearing copper and CuCrZr require separate review rather than being treated as direct substitutes.
Silver plating may be appropriate, but its composition, hardness, thickness and undercoat must match the contact duty. Mating materials, contact pressure, wear and environment also affect performance. Tin and nickel finishes should not be assumed to provide equivalent sliding-contact behavior.
There is no universal rating based on its outline or copper grade. Current capacity depends on section, contact resistance, cooling and permissible temperature rise. Voltage suitability depends on insulation, clearances, creepage and the complete equipment design.
Provide the drawing, material grade and condition, dimensions, quantity, tip geometry, hole pattern, nominated screws and surface treatment. Include contact duty, operating conditions, critical tolerances, inspection documents, destination and requested delivery schedule.
Request a Quote
| Required Information | Details to Provide |
|---|---|
| Drawing | Dimensioned 2D drawing and, where available, a 3D model |
| Material | Copper grade, standard, temper and required conductivity or hardness |
| Overall Dimensions | Length, width, thickness and dimensional datums |
| Curved Tip | Tip rise, included angle, transition radius and single- or double-end configuration |
| Mounting Holes | Quantity, diameter, pitch, countersink angle and depth |
| Fasteners | Screw standard, size, head geometry and permitted head projection or recess |
| Contact Requirements | Contact zones, mating material, contact pressure and sliding or switching duty |
| Surface Finish | Roughness, coating type, thickness, coverage and masking |
| Quantity | Prototype quantity, batch quantity and estimated annual usage |
| Inspection | Critical dimensions, functional tests and required reports or certificates |
| Delivery | Destination, packaging requirements and requested schedule |
Contact Cymber Metal for a drawing-based quotationfor your custom curved-tip copper contact blade.