Custom Copper Stationary Blade Contact with L-Bent Terminal Wing
Video
Short Description
This custom copper stationary blade contact combines an upright blade, a four-hole countersunk base and a terminal wing bent approximately 90 degrees. Beveled blade edges provide a drawing-defined lead-in for the mating contact, while the bent wing provides an orthogonal bolted connection. Material grade, blade thickness, hole geometry, bend radius and surface treatment are specified according to the approved equipment drawing.
Product Overview
A copper stationary blade contact forms the fixed side of a blade-and-mating-contact interface. This design combines an inverted-T blade-and-base arrangement with an L-bent terminal wing, bringing the contact interface and busbar connection into different planes.
The illustrated component has four conical countersunk holes arranged in two rows on the base. The bent terminal wing includes a separate through-hole. The central blade has beveled edges, with its working thickness, lead-in geometry and engagement length defined by the mating assembly.
SuitablePure Coppergrades can be evaluated against conductivity, forming and contact requirements. C11000 and oxygen-free grades such as C10200 are potential material choices, subject to the specified standard, temper and order requirements.
An integral blade-and-base design can be specified where a one-piece current path is required. The starting profile, local machining and bending sequence must be reviewed before production. Electrical ratings and suitability for switching or arcing duty require equipment-level validation.
Key Features
| Feature | Design Relevance |
|---|---|
| Upright Contact Blade | Provides a defined mating interface whose thickness and position can be controlled against the assembly drawing. |
| Four-Hole Countersunk Base | Can accommodate flush-head fasteners when countersinks and screw geometry are correctly matched. |
| L-Bent Terminal Wing | Provides an orthogonal busbar connection within the component’s overall geometry. |
| Beveled Lead-In | Helps guide initial engagement within the permitted alignment range of the mating system. |
| Integral Blade-and-Base Option | Allows a one-piece construction requirement to be considered during material and process planning. |
| Application-Specific Finishing | Allows working faces, fastener seats and plated areas to be specified separately. |
Manufacturing Process
The manufacturing plan coordinates the blade interface, formed terminal wing and mounting holes. The final operation sequence depends on the approved drawing and selected material condition.
| Stage | Manufacturing Activity | Main Consideration |
|---|---|---|
| 1. Engineering Review | Review the blade, base, terminal wing, mating contact and mounting arrangement. | Identify functional datums and dimensions that must be controlled after bending. |
| 2. Material and Blank Selection | Select the copper grade, temper and suitable starting form. | A profiled blank may be evaluated for an integral blade-and-base design. |
| 3. Local Machining | Prepare the contour and remove material where required for the terminal-wing bend. | Preserve the specified blade root and adequate material around the bend. |
| 4. Terminal-Wing Forming | Form the connection wing to the required angle and offset. | Review bend radius, springback, tooling access and material condition. |
| 5. Critical Feature Finishing | Finish the blade faces, lead-in edges, countersinks and terminal hole. | Post-forming machining may be selected to control spatial relationships. |
| 6. Surface Treatment | Deburr, clean and apply the ordered surface finish. | Account for plating thickness on the final blade dimensions and mating fit. |
| 7. Final Inspection | Inspect the completed component against the agreed plan. | Verify functional geometry in the finished condition. |
TheFine Machiningscope can be reviewed around the blade working faces, hole locations and connection surfaces. Specified coating requirements can also be discussed through theBusbar Plating Shop.
Manufacturing & Quality Control
| Control Area | Inspection / Review | Acceptance Basis |
|---|---|---|
| Drawing Control | Confirm revision, datums, blade working area and critical dimensions. | Approved drawing and purchase order |
| Material Identification | Review the ordered copper grade, temper and required supporting documents. | Agreed material specification |
| Blade Thickness | Measure the working section at defined locations, including coating where applicable. | Finished-part thickness tolerance |
| Blade Geometry | Check lead-in profile, edge condition and engagement dimensions. | Mating-contact requirements |
| Formed Terminal Wing | Check angle, offset and relevant positional relationships. | Drawing-defined geometric requirements |
| Bend and Blade-Root Condition | Examine accessible areas for visible forming or machining defects. | Agreed inspection criteria; additional testing when specified |
| Countersunk Base Holes | Check hole diameter, position, countersink angle and major diameter. | Specified fastener and drawing requirements |
| Terminal Through-Hole | Check diameter, location and edge treatment. | Approved terminal connection details |
| Contact Surfaces | Check specified roughness, flatness, cleanliness and burr condition. | Working-face acceptance requirements |
| Plating, When Ordered | Inspect thickness, coverage, masking and other agreed characteristics. | Order-specific coating specification |
| Final Documentation | Prepare agreed dimensional, material and inspection records. | Contract requirements |
Electrical resistance, conductivity, coating adhesion or additional nondestructive testing should be specified where required. Inspection scope and sampling must be agreed before production. Further quality information is available underQuality Assurance.
Typical Applications
| Application | Potential Function | Required Design Review |
|---|---|---|
| Draw-Out Switchgear Assemblies | Stationary blade interface with an orthogonal busbar connection | Contact alignment, engagement length, temperature rise and insulation clearances |
| Circuit-Breaker Connection Bases | Fixed conductive terminal within a drawing-defined connection system | Equipment compatibility, contact pressure and mechanical loading |
| Plug-In Distribution Assemblies | Blade-type connection between removable and stationary sections | Mating-contact geometry, insertion force and operating cycles |
| Industrial Rectifier Cabinets | Custom fixed contact or right-angle terminal connection | Continuous current, cooling conditions and joint resistance |
| Renewable-Energy Power Equipment | Drawing-based connection within converter or distribution assemblies | Thermal performance, fault loading and environmental conditions |
These are potential uses, not approvals for a particular equipment type. Load interruption, earthing-switch duty and arc exposure require separate design assessment and validation.
Frequently Asked Questions
A copper stationary blade contact is the fixed conductive blade engaged by a compatible moving or plug-in contact. This version combines the blade with a mounting base and a bent terminal wing. Its suitability depends on the mating interface, contact pressure, operating conditions and equipment design.
The defining feature is its upright working blade, which must match a mating contact rather than serve only as a bolted connection. Blade thickness, surface condition, lead-in geometry and engagement position therefore require specific control alongside the base holes and bent terminal wing.
No. A countersunk hole has a conical recess, typically matched to a flat-head screw. A counterbored hole has a cylindrical recess with a flat shoulder. The four base holes shown here are countersunk. Screw-head clearance depends on matching the countersink dimensions to the selected fastener.
C11000 and oxygen-free copper grades such as C10200 can be evaluated according to conductivity, forming and joining requirements. The exact grade, standard and temper should be stated on the order. Alternative alloys require a separate assessment because conductivity, strength and contact performance are not interchangeable.
An integral blade-and-base construction can be evaluated using a suitable profile or another approved starting form. Local machining and terminal-wing bending may form part of the route. The drawing should explicitly state any one-piece or no-weld requirement so manufacturing feasibility and inspection can be agreed.
Silver plating may be specified for a contact interface, but it is not automatically required for every design. Coating selection depends on contact pressure, sliding duty, environment and mating materials. Specify plating composition, hardness where relevant, thickness, coverage and finished blade dimensions rather than relying on a generic finish description.
Tolerances must be reviewed against the drawing, particularly for blade thickness, working-face geometry, terminal-wing position and hole locations. Forming and plating can affect the final dimensions. Critical requirements should identify the inspection datums and whether acceptance applies before or after surface treatment.
Potentially, but neither rating can be established from its appearance alone. Current capability depends on conductor section, contact resistance and thermal conditions. Voltage suitability depends on the complete insulation arrangement and clearances. A stationary connection contact must not be assumed suitable for interrupting current or sustained arcing duty.
RFQ Information
| Information Required | Details to Provide |
|---|---|
| Drawing and Revision | Dimensioned PDF and available STEP or other 3D model |
| Material Requirement | Copper grade, applicable standard, temper and required properties |
| Blade Interface | Working thickness, contact length, height, lead-in geometry and mating-contact details |
| Base Geometry | Length, width, thickness and four-hole pattern |
| Countersink Details | Through-hole diameter, included angle, major diameter and fastener specification |
| Bent Terminal Wing | Length, angle, internal radius, offset and through-hole details |
| Critical Tolerances | Datums, blade alignment, contact-face requirements and finished-condition dimensions |
| Surface Treatment | Coating material, thickness, coverage, masking and contact-face requirements |
| Operating Conditions | Current, thermal limits, contact pressure, insertion cycles and environmental exposure |
| Construction Requirement | Any integral, one-piece or no-weld requirement |
| Quantity and Delivery | Sample quantity, batch volume, destination and target delivery date |
| Quality Documents | Required material certificates, inspection reports and testing scope |
Send your drawing, mating-contact requirements and order quantity throughContact Usfor technical review and quotation.