Parameter Specification / Customization Basis
Product Type Round-to-flat copper busbar connector / conductive terminal rod
Material Pure copper; exact grade and temper according to the approved specification
Main Geometry Cylindrical shank with a stepped threaded end and flattened connection palm
Threaded Interface Female thread; standard, size, pitch, tolerance class and engagement depth specified by drawing
Socket Construction Bore diameter, bore depth and minimum wall thickness defined by design
Palm Configuration Two through-holes with a rounded external outline
Palm Dimensions Width, thickness, length and contact area according to the mating assembly
Mounting Pattern Hole diameter, center distance and edge distance according to drawing
Transition Geometry Round-to-flat transition with specified radii and section dimensions
End Step / Relief Diameter, width and function defined by drawing; not automatically a sealing feature
Electrical Contact Surfaces Identified separately for the threaded end and bolted palm
Surface Finish Bare copper, specified machining finish or an approved optional plated finish
Dimensional Tolerances Feature-specific requirements established during drawing review
Electrical Rating Determined by the complete assembly, operating conditions and validation requirements

Product Detail

Product Tags

Video

Short Description

Custom round-to-flat copper busbar connector featuring a long cylindrical shank, a stepped female-threaded end and a flattened two-hole connection palm. The component provides a transition between a round conductor interface and a bolted flat connection. Copper grade, thread geometry, palm dimensions, hole spacing and surface finish are specified according to the approved drawing and mating assembly requirements.

Product Overview

This round-to-flat copper busbar connector combines two connection geometries in one elongated conductor: an internally threaded cylindrical end and a flat, two-hole terminal palm. The shaped transition connects the round shank to the wider palm, while the stepped socket end accommodates the specified mating threaded component.

Material selection starts with the requiredPure Coppergrade, temper and electrical properties. The design should also define the current-carrying contact surfaces, minimum section around the threaded bore, palm thickness and remaining material around the mounting holes.

A one-piece construction can be specified for manufacturing review. The production route, dimensional tolerances and inspection requirements are agreed against the drawing rather than inferred from the product’s external appearance.

Key Features

Feature Practical Value
Round-to-Flat Configuration Connects cylindrical conductor geometry to a flat bolted interface.
Female-Threaded Socket Accommodates a matching threaded component with defined engagement requirements.
Two-Hole Connection Palm Provides two fastening locations and rotational restraint within the assembled joint.
Shaped Transition Allows the round shank and wider terminal palm to be integrated into the specified conductor layout.
Stepped Cylindrical End Provides a configurable interface for assembly positioning or mating-part clearance.
Drawing-Based Construction Allows critical contact faces, tolerances and connection details to match the equipment design.
Optional Surface Treatment Supports application-specific contact-surface and corrosion-protection requirements.

Joint security depends on the complete fastening system, including bolt selection, preload, copper temper and service conditions. A two-hole pattern alone does not guarantee resistance to loosening.

Manufacturing Process

The manufacturing route is selected after reviewing the copper grade, section changes, overall length and required quantities. End forming or forging may be combined with machining where technically suitable.

Stage Process Scope
1. Drawing Review Confirm interfaces, dimensions, current-carrying sections, material and inspection requirements.
2. Material Preparation Select copper stock with the specified grade, temper and traceability requirements.
3. Preform Production Evaluate suitable stock preparation and local forming for the widened palm and end geometry.
4. Cylindrical-End Machining Machine the shank features, end steps, bore and internal thread.
5. Palm Machining Produce the contact faces, external profile, through-holes and transition details.
6. Deburring and Finishing Remove burrs and apply the specified edge treatment and surface finish.
7. Optional Plating Apply the approved coating system to defined surfaces when required.
8. Final Inspection Inspect agreed characteristics and prepare the specified shipment documentation.

Threading, drilling and contact-face finishing can be reviewed through Cymber Metal’sFine Machiningservice. Optional coating requirements can be discussed with theBusbar Plating Shop, including coating type, thickness, masking and post-plating dimensions.

Manufacturing & Quality Control

Control Area Inspection / Verification Scope
Material Identification Verify the specified copper grade, temper and required material documentation.
Overall Dimensions Check overall length, shank diameter, stepped-end dimensions and palm geometry.
Internal Thread Verify thread form, pitch, class and usable engagement using the agreed inspection method.
Socket Wall Section Check bore depth and the remaining material around the threaded socket.
Palm Hole Pattern Inspect hole diameter, center distance, position and edge distance.
Contact Surfaces Check specified flatness, surface texture and cleanliness on designated contact areas.
Interface Alignment Inspect the relationship between the threaded-end axis, shank and palm datums.
Edges and Surface Condition Check for burrs, sharp edges and unacceptable surface damage.
Plating, When Specified Verify agreed coating thickness, coverage, masking and dimensional allowance.
Additional Testing Conductivity, hardness or nondestructive testing can be included in the agreed inspection plan.
Shipment Records Supply inspection and material records as specified in the purchase requirements.

Inspection scope and acceptance criteria are established before production. SeeQuality Assurancefor Cymber Metal’s quality-control approach.

Typical Applications

The following are potential applications. Final suitability depends on the equipment design and assembly validation.

Application Potential Connection Role Main Design Considerations
Switchgear Assemblies Transition between a round conductor and flat busbar connection Contact area, clearances, temperature rise and fastening arrangement
GIS Conductor Assemblies Custom internal conductor transition Electric-field geometry, insulation coordination and separately specified sealing requirements
Vacuum Circuit-Breaker Assemblies Drawing-specific terminal or conductor connection OEM interface geometry, mechanical loading and contact requirements
Transformer and Reactor Bushings Connection between a bushing conductor and a flat terminal interface Thread engagement, installation loads and current-carrying surfaces
Disconnectors Rigid conductor-to-terminal transition Alignment, fastening security and operating loads
Industrial Power Equipment Custom connections in rectifiers, converters or induction equipment Duty cycle, cooling conditions and thermal expansion

Frequently Asked Questions

What is a round-to-flat copper busbar connector?

It is a rigid copper conductor that transitions from a cylindrical section to a flattened terminal palm. This design also includes a female-threaded socket at the cylindrical end and two mounting holes in the palm.

Can this connector be manufactured as one piece?

A one-piece construction can be specified for review. Feasibility depends on the copper grade, section changes, dimensions and selected manufacturing route. Any requirement for a weld-free component should be stated explicitly on the drawing or purchase specification.

Which copper grade should be specified?

Select the grade according to conductivity, mechanical properties, forming requirements and service conditions. The applicable material standard and temper should be stated explicitly. Copper grades from different designation systems should not be treated as automatically interchangeable.

What information is needed for the internal thread?

Specify the thread standard, nominal size, pitch, tolerance class, thread direction and effective engagement depth. The drawing should also identify the mating component, seating arrangement and electrical contact surfaces. Installation torque requires a joint-specific assessment.

Why does the flat palm have two holes?

Two fastening locations help position the joint and provide rotational restraint. Reliable service still depends on suitable hardware, controlled preload, contact-surface preparation and allowances for copper deformation and thermal cycling.

Can the contact surfaces be silver-plated or tin-plated?

Silver or tin plating can be reviewed according to the application. Specify the coating system, thickness, plated areas and masking requirements. Thread dimensions and fit must account for any coating applied to the threaded interface.

Is the stepped end suitable for gas-tight GIS service?

Not automatically. An external step or annular relief does not establish a validated seal. Gas-tight service requires defined seal geometry, suitable sealing materials, surface requirements and assembly-level leak testing. The photos do not establish a voltage or pressure rating.

What should be provided for a quotation?

Provide a dimensioned drawing, copper grade, quantity, thread specification, palm hole pattern, contact-surface requirements and any plating or inspection requirements. Information about the mating components and operating environment helps resolve interface questions before production.

RFQ Information

Required Information Details to Provide
Drawing Files Dimensioned PDF and STEP or another suitable 3D format, when available
Copper Material Grade, material standard, temper and required properties
Quantity Prototype quantity, order quantity and expected annual demand
Overall Geometry Length, shank diameter, end steps and round-to-flat transition dimensions
Thread Details Standard, size, pitch, class, direction and engagement depth
Socket Details Bore depth, wall thickness and mating-component requirements
Palm Connection Width, thickness, hole diameter, hole spacing and contact area
Critical Datums Alignment, position and contact-face requirements
Surface Treatment Bare copper or specified coating, thickness and masking
Service Conditions Current duty, temperature, mechanical loads and installation environment
Quality Documentation Required material records, inspection reports and additional testing
Delivery Requirements Destination, packaging requirements and target delivery date

Send your drawing and quantity throughContact Usfor material, manufacturing and quotation review.