Copper Saddle Clamp for Tubular Busbars
Video
Short Description
Cymber Metal supplies custom copper saddle clamp half-shells for tubular busbars and cylindrical conductors. Produced from specifiedpure copper, each component combines a semi-cylindrical inner contact surface with an external connection face.
Mating diameter, wall thickness, connection boss and hole pattern are customized to approved drawings. Circular-boss and multi-hole flat-face variants can be reviewed, with optional plating and inspection requirements defined for the intended assembly.
Key Features
- Semi-cylindrical contact geometry for tubular or round conductors.
- Custom connection boss, flat contact face and hole arrangement.
- Copper grade and condition selected for the specified electrical and mechanical requirements.
- Optional plated contact surfaces, with finished dimensions defined after coating where required.
Manufacturing & Quality Control
| Stage | Scope |
|---|---|
| Drawing and Fit Review | Confirm conductor diameter, arc coverage, mating half, assembly gap, clamping arrangement and critical datums |
| Material and Blank Selection | Agree grade, condition and suitable wrought or forged stock; cast alternatives require a separately agreed cast-material specification |
| CNC Machining | UseCNC machining supportfor the inner arc, connection face, holes and split faces; fixtures and sequence selected to suit the geometry |
| Finishing | Deburr and clean; apply agreed plating with defined coverage, masking and thickness |
| Final Inspection | Check drawing-defined geometry and surface condition; complete agreed material, fit and coating checks before protective packing |
For inspection methods and available documentation, see ourQuality Assurancepage. Product-specific testing and acceptance criteria are confirmed before order placement.
Typical Applications
- Tubular busbar connection nodes in switchgear and GIS assemblies.
- Tubular-to-flat busbar transition interfaces.
- Drawing-specific contact shoes for cylindrical conductors and circuit-breaker rods.
- Electrode contact components for industrial heating and furnace equipment.
Suitability depends on joint design, clamping load, operating temperature and equipment-level electrical validation. Cooling passages are not implied by the photographed holes.
Copper Saddle Clamp FAQ
It provides a shaped conductive interface between a round conductor and a mating connection component. The inner arc seats against the conductor, while an external face or boss connects to the surrounding assembly. The complete joint design determines how it is clamped and how current is transferred.
The photographs show individual half-shell components, not a complete bolted clamp assembly. Specify whether you need one half-shell, matched halves or an assembly with hardware. Mating parts, split gap and fastening details must be defined before production.
C11000, C10200 and C10100 can be reviewed against conductivity, material condition, joining process and mechanical requirements. C18150 can be considered separately where greater strength or softening resistance is needed; it is a copper alloy, not an interchangeable pure-copper grade.
Yes, subject to drawing review. Specify the conductor diameter, arc coverage, length, wall thickness, connection-face geometry and hole pattern. Circular-boss and multi-hole flat-face designs are different variants and should have separate drawing references.
Arc profile, face flatness, alignment and roughness are reviewed individually. Provide conductor tolerances, assembly gap, datums and the required fit-check method. Acceptance should state whether measurements apply before or after plating; a universal tolerance or contact-area percentage is not assumed.
No fixed rating is established by the copper grade or photographs alone. Current capacity, joint resistance and temperature rise depend on geometry, fit, surface condition and clamping load. Equipment voltage suitability also requires assessment of insulation clearances and the complete assembly.
Full or selective silver or tin plating can be reviewed. Specify the contact areas, coating thickness, masking, undercoat and applicable coating standard. Coating allowance must be included in the mating dimensions; plating alone does not establish the electrical performance of the joint.
Material certificates, dimensional reports and coating records can be agreed with the order. Conductivity, contact-fit checks, internal-soundness testing and third-party inspection require defined methods and acceptance criteria. EN 10204 Type 3.1 documentation must be confirmed before ordering.
Request a Quote
Contact Cymber Metalwith your 2D/3D drawing, copper grade and condition, mating-conductor dimensions, quantity, half-shell or assembly scope, critical tolerances, hole details, plating requirements, inspection documents, destination and target delivery date. Include operating current, allowable temperature rise and clamping conditions where relevant.