Custom Flanged Copper Terminal with D-Cut Stem

Short Description:

Parameter Reference Specification / Requirement
Product Type Custom flanged copper terminal / conductive pedestal connector
Main Geometry Circular flange, cylindrical transition section, and upper D-cut stem
Pictured Flange Layout Four peripheral mounting holes with underside side-open recessed pockets
Central Attachment Feature Axial internal thread on the underside of the flange
Upper Connection Interface Flat contact pad with a lower shoulder and two transverse tapped holes
Construction Option One-piece machining from solid stock, subject to drawing and process confirmation
Primary Material Options C11000, C10200, or C10100
Alternative Materials C10400, C10700, C14500, or C18150 may be evaluated; these are not equivalent substitutes
Flange Outside Diameter Reference range: 30–220 mm
Stem Diameter Reference range: 15–140 mm
Total Height Reference range: 30–300 mm
Central Axial Thread Reference range: M8–M48; pitch, depth, and engagement length by drawing
Transverse Threads Reference range: M6–M24; quantity and spacing by drawing
Thread Specification Metric ISO 965, such as 6H, or ASME B1.1 Class 2B where specified
Turned-Diameter Tolerance Reference target: ±0.015 to ±0.03 mm on designated features
Contact-Pad Perpendicularity Reference target: ≤0.02 mm relative to the specified flange datum, over the defined feature length
Central Thread Coaxiality Reference target: ≤0.015 mm relative to the specified datum axis; inspection method to be agreed
Contact-Surface Roughness Reference target: Ra 0.2–0.4 μm; specify the required maximum for each functional surface
Hardness Reference target: 85–125 HV, dependent on grade, condition, and test location
Electrical Conductivity Requirement and verification method agreed for the selected material and condition
Surface Options Bare copper, agreed anti-tarnish treatment, silver plating, tin plating, or nickel plating
Silver-Plating Thickness Reference option: 5–30 μm, subject to coating specification and feasibility review
Material Standard Selected according to grade and starting form, such as ASTM B187/B187M where applicable
Inspection Documents Material records, dimensional reports, thread inspection results, and coating reports as agreed

Product Detail

Product Tags

Video

Short Description

This custom flanged copper terminal combines a circular mounting flange, a cylindrical transition section, and an upper D-cut stem with a flat connection pad and two transverse tapped holes. The flange includes a central axial threaded hole and four mounting holes with side-open recessed pockets on the underside.

The component provides a drawing-based conductive interface for busbar connections, bushing assemblies, and other electrical equipment. Material options include C11000, C10200, and C10100 copper, with machining, thread fit, contact-surface finish, and optional plating reviewed against the application requirements.

Product Overview

A flanged copper terminalcombines a conductive post with a mounting flange, allowing the electrical connection and mechanical attachment interfaces to be defined within one component design.

The pictured version has a circular base with four peripheral mounting holes. Side-open recessed pockets on the underside provide space around these holes for the specified mounting hardware. A central axial threaded hole offers an additional attachment interface where required by the assembly design.

The upper stem has a milled flat that creates a D-shaped section. This flat provides a mating surface for a busbar or another conductor, while two transverse tapped holes support the specified bolted connection. A shoulder below the flat can serve as a locating surface when matched to the adjoining part.

A one-piece machined construction can be specified to avoid a separate flange-to-stem joint. Starting material, machining sequence, and final construction should be confirmed during drawing review.

Explore Cymber Metal’spure copper productsfor material options andFine Machiningfor custom component processing.

Key Features

Feature Design Purpose Engineering Consideration
Circular Mounting Flange Provides a defined mounting interface around the conductive post Flange thickness, bolt circle, and support conditions must suit the applied loads
Central Axial Thread Provides a stud or fastener attachment interface Thread engagement, tightening torque, and copper condition require review
Four Peripheral Mounting Holes Supports a distributed fastening arrangement Hole positions and access must match the mating assembly
Side-Open Recessed Pockets Provides local clearance for specified mounting hardware Pocket depth, remaining wall thickness, and fastener seating must be defined
D-Cut Upper Stem Creates a flat surface for a mating conductor Contact area, orientation, flatness, and surface finish require control
Dual Transverse Tapped Holes Supports a two-fastener connection layout Thread strength and permitted bolt preload depend on the complete joint
Lower Contact-Pad Shoulder Can provide a locating or supporting reference Its locating function depends on the mating conductor geometry
Optional One-Piece Construction Avoids a separate flange-to-stem joining operation Does not independently establish electrical or mechanical ratings
Optional Plating Adapts the contact surface to the specified joint environment Coating thickness, masking, and final thread fit must be coordinated

Manufacturing Process

The machining route should maintain the relationship between the flange datum, stem axis, contact pad, and threaded features.

Stage Process Scope Main Review Point
Drawing and Datum Review Define flange surfaces, stem axis, contact pad, holes, and thread requirements Establish measurable functional tolerances and inspection references
Material Selection Select copper grade, condition, and suitable starting stock Balance conductivity, thread strength, machinability, and material cost
Blank Preparation Prepare stock with appropriate machining allowance Maintain material identification and sufficient allowance for finishing
Turning Produce the flange, stem, shoulders, and axial features Control diameters and their relationship to the selected datum axis
Milling Produce the upper flat, shoulder, and flange recesses Control contact-pad orientation, pocket geometry, and hole locations
Thread Production Machine the axial and transverse internal threads Define thread class, usable engagement, and blind-hole depth where applicable
Deburring and Finishing Finish contact surfaces and remove burrs at hole and thread exits Pay particular attention to transverse holes exiting through curved surfaces
Surface Treatment Apply the agreed cleaning, anti-tarnish treatment, or plating Account for coating buildup and any masked contact or threaded areas
Final Inspection and Packing Verify agreed characteristics and protect finished surfaces Prevent damage to threads, flange seating faces, and the contact pad

Turn-mill machining or coordinated turning and milling may be selected according to the design. Machine configuration and setup count should be confirmed rather than assumed from the finished geometry.

For coating-related processing, review Cymber Metal’sBusbar Plating Shop. Finish selection should consider the mating material, operating environment, and required joint performance.

Manufacturing & Quality Control

The inspection plan should identify critical characteristics, measurement methods, and sampling requirements before production.

Control Area Inspection / Verification Acceptance Basis
Material Identification Review grade, condition, and material documentation Approved material specification and order requirements
Material Properties Verify conductivity, hardness, or composition where specified Agreed test methods and grade-specific acceptance criteria
Overall Dimensions Measure flange diameter, thickness, stem diameter, and total height Approved drawing
Flange Mounting Pattern Check hole diameter, bolt-circle location, spacing, and recess dimensions Drawing datums and positional requirements
Central Thread Check thread size, pitch, engagement depth, and specified axis relationship Approved thread specification and geometric requirements
Transverse Threads Check thread fit, center spacing, location, and usable engagement Drawing and agreed thread-gauging plan
D-Cut Contact Pad Check flatness, shoulder position, and perpendicularity to the flange datum Defined functional-surface requirements
Surface Finish Measure specified roughness and inspect contact and mounting surfaces Surface-specific acceptance limits
Burr Control Inspect pocket edges, hole intersections, and curved-surface thread exits Agreed burr and edge-break requirements
Coating Quality Check thickness, coverage, adhesion, and masked areas where specified Approved coating specification
Internal Soundness Perform ultrasonic or other suitable inspection when required and technically applicable Agreed procedure, coverage, and acceptance criteria
Assembly Validation Evaluate thread loading, joint resistance, or temperature rise where required Actual mating parts and an agreed test procedure
Traceability and Records Review batch identification and required inspection reports Agreed documentation package

Review ourQuality Assurancepage for background on Cymber Metal’s quality approach. Product-specific testing, traceability, and documentation requirements should be confirmed before ordering.

Typical Applications

These are potential application areas, subject to equipment-specific design review and qualification. The component is not assigned a universal voltage, current, short-circuit, or pressure-sealing rating.

Application Potential Component Role Required Confirmation
Vacuum Circuit-Breaker Pole Assemblies Conductive terminal or transition component within a pole assembly Electrical interface, temperature rise, mechanical loading, and dielectric design
Gas-Insulated Switchgear Bushing Assemblies Conductive connection between a bushing interface and busbar Insulation coordination, gas compatibility, sealing arrangement, and joint performance
Post-Insulator Busbar Supports Flanged connection post with a flat busbar interface Insulator loading, bolt preload, mounting geometry, and clearances
Epoxy-Embedded Electrical Assemblies Conductive insert with drawing-specific mounting features Resin compatibility, thermal cycling, electric-field control, and retention testing
Industrial Power Converters Custom conductive transition terminal Current duty, cooling conditions, connection resistance, and mounting loads
Induction Power Equipment Connection post between conductors or equipment interfaces Frequency-dependent losses, thermal behavior, vibration, and joint qualification

FAQ

What is a flanged copper terminal?

A flanged copper terminal is a conductive component that combines a mounting flange with a terminal post. This version includes a D-cut upper contact pad, two transverse tapped holes, a central axial thread, and four flange mounting holes. It is a connection component, not a complete insulating bushing or switching device.

Why does the upper stem have a D-cut flat?

The flat creates a mating surface for a busbar or another conductor. Its orientation allows the connection face to be positioned relative to the flange. The shoulder below the flat can provide a locating reference, but contact pressure, alignment, and mechanical support depend on the complete bolted-joint design.

How is the circular flange attached to the mating assembly?

The design provides a central axial threaded interface and four peripheral mounting holes. The equipment drawing determines which features are used and how loads are distributed. Fastener access, engagement length, seating surfaces, tightening sequence, and permitted torque should be established for the actual assembly.

Do the side-open flange pockets provide an epoxy interlock?

They may contribute to mechanical retention if incorporated into a suitable embedded design, but their presence alone does not establish pull-out or anti-rotation strength. Resin properties, pocket geometry, cure conditions, thermal cycling, and electric-field requirements must be considered. Retention performance requires validation against defined acceptance criteria.

Can the flange and stem be machined as one piece?

A one-piece construction can be evaluated from suitable solid stock. This avoids a separate flange-to-stem joint, but it does not guarantee resistance to every mechanical or thermal load. Final feasibility depends on dimensions, stock availability, material condition, machining access, and the required inspection scope.

Which copper grade is suitable for this terminal?

C11000, C10200, and C10100 can be evaluated for conductive terminal applications. Material condition and thread loading are important alongside conductivity. C10400, C10700, C14500, or C18150 may be considered for different machining, strength, or thermal requirements, but they should not be treated as interchangeable grades.

Is this terminal automatically suitable for 12–40.5 kV equipment or a specified short-circuit current?

No. Equipment voltage and short-circuit capability cannot be established from the terminal’s shape or material alone. Suitability depends on insulation coordination, conductor arrangement, temperature rise, mechanical forces, mounting conditions, and applicable equipment tests. Any rating must be supported by the complete assembly design and validation.

Can the contact surfaces and threaded holes be plated?

Silver, tin, or nickel plating can be evaluated according to the application. The drawing should define thickness, coverage, masking, and final dimensional requirements. Plating inside threaded holes can change fit, so thread allowances, coating control, and post-coating inspection need to be agreed before production.

Request a Quote

Required Information Details to Provide
Drawing Dimensioned 2D drawing and, where available, a 3D model
Material Copper grade, standard, condition, and required properties
Construction One-piece requirement or any permitted alternative construction
Main Dimensions Flange diameter and thickness, stem diameter, and total height
Mounting Pattern Bolt-circle diameter, hole count, hole sizes, and recess details
Central Thread Size, pitch, class, depth, engagement, and axis requirements
Transverse Threads Size, spacing, position, thread class, and engagement length
Contact Pad Flat dimensions, shoulder location, flatness, roughness, and orientation
Surface Treatment Bare copper or specified coating, thickness, coverage, and masking
Operating Conditions Current, voltage, frequency, temperature, environment, and mechanical loads
Assembly Requirements Mating parts, fastener specifications, installation torque, and mounting method
Inspection and Documents Material records, dimensional reports, coating checks, and any special tests
Quantity and Delivery Sample quantity, batch volume, annual demand, destination, packing, and requested schedule

Contact Cymber Metal for a drawing-based quotationcovering material selection, machining feasibility, thread requirements, surface treatment, and inspection planning.


  • Previous:
  • Next:

  • Write your message here and send it to us