90-Degree Bent Copper Tubular Busbar with Threaded Ends

Short Description:

Item Specification / Enquiry Reference
Product Type Bent tubular copper busbar / hollow copper elbow conductor
Main Configuration 90-degree bend with two straight legs
Cross-Section Hollow circular section
Material Options C11000, C10200 or C10100, subject to the purchase specification
Alternative Grade Designations Cu-ETP, Cu-OF, T2, TU1 or TU2 may be reviewed against the applicable standard; equivalence is not assumed
Starting Tube Standard ASTM B188 or EN 13600 may be specified where applicable
Outside Diameter Reference range: Ø12–Ø160 mm
Wall Thickness Reference range: 2.5–35.0 mm
Developed Length Reference range: 80–4,000 mm
Bend Radius Drawing-specific; reference requests from 1.5 × OD centerline radius require forming review
Leg Lengths Defined independently by the drawing and assembly clearances
Internal Threads Reference range: M8–M90; size, pitch, class and engagement length to be specified
Other Connection Threads BSPP or NPT can be reviewed where required by the mating connection
End Features Stepped outside diameters, shoulders, counterbores and specified thread features
Machined End Diameters Reference tolerance target: ±0.015–0.03 mm on designated features
Bend Angle Reference tolerance target: ±0.2° to ±0.5°, subject to geometry and inspection review
Bend Ovality Reference acceptance range: 3–5%, with calculation method and measurement locations agreed
Surface Roughness Reference target: Ra 0.4–0.8 µm on designated surfaces; bend and machined surfaces specified separately
Conductivity Required IACS value and test method to be agreed for the selected grade and condition
Surface Treatment Cleaned copper; optional anti-tarnish treatment, silver, tin or nickel plating
Optional Silver Thickness Reference range: 5–30 µm, subject to coating specification and coverage
Pressure Requirements Design pressure, temperature, medium and test procedure must be specified separately
Documentation Material and inspection documents according to the purchase order

Product Detail

Product Tags

Video

Short Description

This bent copper tubular busbar features a 90-degree configuration, a hollow circular section and machined end connections. Internal threads and stepped end geometry can be specified to match the surrounding assembly. Material grade, wall thickness, bend radius, leg lengths and surface treatment are reviewed against the drawing for switchgear, power distribution and suitable water-cooled electrical applications.

Product Overview

A bent copper tubular busbar provides a conductive path that changes direction while retaining a hollow cross-section. This design combines an L-shaped body with machined connection features, allowing the conductor geometry and end interfaces to be defined within a single component drawing.

The photographed sample shows a rounded bend, two straight legs and a stepped external diameter near one end. The close-up photographs show an end bore and a clearly visible internal thread at the enlarged end. Exact dimensions, thread specifications and internal passage geometry require drawing confirmation.

Material options can be reviewed within ourpure copper product range. C11000, C10200 and C10100 may be considered according to conductivity requirements, forming condition and any subsequent brazing or thermal processing.

Cymber Metal’scopper machining supportcan support drawing review for end diameters, threads, shoulders and other connection features. Current-carrying capacity, pressure suitability and equipment compatibility must be established for the intended assembly.

Key Features

Feature Product Detail / Buyer Consideration
90-Degree Conductive Path Changes the direction of a tubular conductor within a drawing-defined assembly
Hollow Circular Section Provides an internal passage that may be used for cooling when the component is designed and tested for that purpose
Machined Threaded Connections Thread size, class, engagement length and mating interface can be specified
Stepped End Geometry End diameters and shoulders can be matched to connection or positioning requirements
Drawing-Based Bend Geometry Bend radius, leg lengths and end orientation are defined around the installation envelope
Material Selection Copper grade and condition are selected for electrical, forming and subsequent processing requirements
Continuous-Tube Bend Option A bend formed from continuous tube can be specified where an elbow joint is not permitted
Optional Contact-Area Plating Coating type, thickness and coverage can be reviewed for designated connection surfaces

A continuous-tube construction requirement should be stated explicitly. Photographs alone do not establish the starting material route or verify the absence of joints.

Manufacturing Process

Stage Process / Control Focus
Technical Review Confirm material, tube dimensions, bend radius, leg lengths, threads, sealing interfaces and critical tolerances
Starting Material Selection Select suitable copper tube with the required grade, condition and documentation
Blank Preparation Cut the tube to the required allowance and establish material identification
Forming Preparation Review tooling, tube condition and the need for internal support during bending
Tube Bending Form the required bend using a process suitable for the diameter, wall thickness and radius
Post-Bend Inspection Check bend angle, leg position, ovality and accessible wall-thickness locations
End Machining Machine the specified end diameters, shoulders, bores, counterbores and threads
Cleaning and Edge Finishing Remove burrs and machining residue; clean accessible internal and external surfaces
Optional Surface Treatment Apply the agreed coating or surface protection, accounting for final dimensional requirements
Final Verification and Packing Inspect the ordered characteristics and protect threads, bores and contact surfaces for shipment

For related finishing options, see ourbusbar plating shop. Coating coverage inside bores and threads requires separate review.

Manufacturing & Quality Control

Inspection Area Proposed Verification Acceptance Basis
Material Identification Review material documentation and agreed composition checks Specified grade, standard and condition
Oxygen Content Use an appropriate oxygen-analysis method when required Specified limit and agreed test method
Starting Tube Dimensions Check outside diameter, wall thickness and relevant tube condition Approved starting-material specification
Bend Geometry Measure bend angle, leg lengths and relative end positions Drawing datums and tolerances
Bend Ovality Measure the cross-section at agreed bend locations Defined ovality formula and acceptance limit
Wall Thickness After Bending Check accessible locations using an agreed method Minimum permitted wall thickness
Machined End Dimensions Measure end diameters, shoulders and counterbores Approved drawing
Thread Quality Use suitable gauges or an agreed inspection method Thread standard, size, class and engagement length
Surface Condition Inspect for unacceptable cracks, wrinkles, burrs and handling damage Agreed workmanship criteria
Surface Roughness Measure specified functional surfaces Drawing requirements and measurement conditions
Conductivity Perform testing when required by the order Agreed value, test method and material condition
Leak / Pressure Testing Conduct an agreed test for fluid-service components Specified pressure, medium, duration and acceptance criteria
Additional Nondestructive Testing Review suitable methods where required Order-specific inspection plan
Plating Inspection Check specified thickness, coverage and other coating characteristics Approved coating specification
Documentation Supply the agreed material and inspection records Purchase-order requirements

Routine composition screening alone should not be used to certify low oxygen content. Inspection scope, sampling and reporting are agreed before production. Further information is available on ourquality assurance page.

Typical Applications

These are potential application areas. Final suitability depends on the equipment design, operating conditions and required qualification.

Application Area Potential Component Role Requirements to Confirm
Gas-Insulated Switchgear Bent tubular conductor between drawing-defined interfaces Electric-field design, clearances, thermal performance and equipment qualification
Circuit Breaker Assemblies Direction-changing conductive connection Contact arrangement, connection loads and current duty
Power Distribution Equipment Tubular busbar transition around installation constraints Current rating, supports, temperature rise and fault-load requirements
Induction Heating Equipment Water-cooled electrical conductor Frequency, cooling flow, water quality and pressure requirements
Vacuum Melting / Crystal Growth Equipment Custom power-and-cooling connection Material grade, thermal cycling, cleanliness and joining requirements
Industrial Power Converters Drawing-specific cooled conductor or connection tube Electrical isolation of the cooling circuit, joint design and leakage criteria

Frequently Asked Questions

What is a bent copper tubular busbar?

A bent copper tubular busbar is a hollow copper conductor formed to change the direction of an electrical path. It can incorporate machined ends, threads and shoulders. The internal passage may also serve a cooling function when designed and tested for that application.

How is this different from a standard copper plumbing elbow?

This component is specified around electrical conductor geometry and machined assembly interfaces, rather than a standard plumbing fitting connection. However, its electrical or pressure suitability still requires confirmation; copper material and an elbow shape alone do not establish a rating.

Which copper grade should be selected?

Grade selection depends on conductivity, forming condition, thermal processing and service requirements. C11000 may be considered for many electrical applications. Oxygen-free grades such as C10200 or C10100 may be preferable when subsequent processing raises concerns about hydrogen embrittlement in oxygen-bearing copper.

Are the threads used to create a pressure-tight seal?

Not necessarily. Thread retention and fluid sealing are separate design requirements. Straight metric or BSPP threads commonly require a separate sealing arrangement. Tapered threads also need the correct mating geometry and assembly procedure. The sealing method must be defined in the drawing.

Can the bend be made without a brazed elbow joint?

A bend formed from continuous copper tube can be specified, subject to geometry and forming review. State any restrictions on joints in the enquiry. A continuous bend removes that particular elbow joint but does not eliminate the need to inspect the tube, bend and end connections.

Can the internal passage carry cooling water?

Potentially, provided the component and complete cooling circuit are designed for it. Please specify the medium, pressure, temperature, flow, water quality and leakage criteria. Bore continuity and hydraulic performance cannot be confirmed from the photographs alone.

Can the connection areas be silver plated?

Silver plating can be reviewed for designated connection areas. Please specify thickness, coverage, any underlayer and final thread or fit requirements. Internal surfaces and recessed features may need different coating and inspection arrangements from accessible external surfaces.

What determines the current rating and operating voltage?

Neither rating is determined by the component’s shape alone. Current capability depends on conductive area, joints, cooling, frequency, ambient conditions and permissible temperature rise. Voltage suitability depends on the complete insulation system, clearances, field distribution and equipment testing.

Request a Quote

Required Information Details to Provide
Drawing / CAD File Dimensioned PDF and STEP or other available CAD format
Material Copper grade, applicable standard and required condition
Tube Dimensions Outside diameter, wall thickness and minimum internal passage
Bend Geometry Angle, centerline radius, leg lengths and end orientation
Connection Features Thread size, pitch, class, usable depth, shoulders and counterbores
Critical Tolerances Datums, dimensional limits and geometric requirements
Construction Requirements Any restrictions on joints, brazing or welding
Electrical Conditions Current, frequency, duty cycle and temperature-rise requirements
Cooling Conditions Medium, pressure, temperature, flow and leakage criteria, if applicable
Surface Treatment Coating type, thickness, coverage and contact-surface requirements
Inspection Documents Required material records, dimensional reports and special tests
Quantity and Delivery Prototype / batch quantity, destination and requested schedule

Contact Cymber Metal for a custom conductor quotationwith your drawing, material specification and operating requirements.


  • Previous:
  • Next:

  • Write your message here and send it to us