Copper VCB Terminal Housing with Rectangular Window

Short Description:

Item Specification
Product Copper VCB Terminal Housing / Rectangular-Window Conductive Bracket
Material Options C11000 (ETP), C10200 (oxygen-free) or C10100 (oxygen-free electronic copper) for wrought-material routes; grade and condition as specified
Applicable Standards ASTM B187/B187M for bar or ASTM B152/B152M for plate feedstock, where applicable; forging or casting specifications agreed separately. Finished component acceptance to the approved drawing
Blank and Processing Route CNC finishing of an agreed wrought or forged copper blank; casting alternatives require separate grade and process approval
Overall Length 80–450 mm indicative range; subject to drawing review
Ring Outer Diameter 60–350 mm indicative range
Body Thickness 30–180 mm indicative range; local wall thickness and boss dimensions defined by drawing
Central Window Rounded rectangular through-window; opening size, corner radius and clearance to drawing
Mounting Features Circular hole array on one ring face, end-face hole pattern and radial threaded features; layout and thread details to drawing
Critical Geometry Stepped-face dimensions, flatness, boss-face orientation, hole position and contact-surface roughness confirmed by feature review
Surface Options Machined and deburred; exterior texture, cleaning and anti-tarnish treatment as specified
Plating Options Optional full or selective silver, tin or nickel plating; thickness, masking and finished dimensions agreed before production
Inspection Material verification, window geometry, step dimensions, face alignment, hole locations, threads and surface condition; conductivity, internal-soundness and coating checks as agreed
Documentation Material test certificate, dimensional report and coating records as specified; EN 10204 Type 3.1 documentation subject to order confirmation

Product Detail

Product Tags

Video

Short Description

Cymber Metal supplies custom copper VCB terminal housings for vacuum circuit-breaker conductive assemblies. Machined from specifiedpure copper, the body combines a ring section, a rounded rectangular through-window, stepped faces and a cylindrical connection boss.

Window dimensions, mounting-hole patterns, contact surfaces and optional plating are prepared to approved drawings. The component can be reviewed for moving-end outgoing connections or flexible-shunt interfaces; fit, current capacity and insulation requirements depend on the complete assembly.

Key Features

  • Rounded rectangular through-window for drawing-defined mating-part clearance.
  • Stepped ring faces and a cylindrical connection boss within one conductive body.
  • Mounting features on multiple faces for application-specific connections.
  • Custom contact surfaces, thread details and optional selective plating.

Manufacturing & Quality Control

Stage Scope
Drawing and Material Review Confirm copper grade, condition, blank route, mating parts and critical contact surfaces
CNC Machining UseCNC machining supportfor the ring steps, rectangular window, boss face and multi-face hole pattern
Finishing and Cleaning Deburr window edges and threads, remove chips and machining residues, then apply the agreed surface treatment
Final Inspection Verify drawing-defined geometry, thread requirements and contact faces; complete agreed material/coating checks and protect functional surfaces for shipment

For inspection methods and available documentation, see ourQuality Assurancepage. Product-specific testing and acceptance criteria are confirmed before order placement.

Typical Applications

  • Moving-end outgoing conductive connections in vacuum circuit-breaker assemblies.
  • Flexible copper shunt and terminal interfaces in embedded-pole designs.
  • Drawing-specific conductive connection nodes in switchgear and disconnectors.

Each application requires review of the mating parts, current path, mechanical loads and insulation arrangement.

Copper VCB Terminal Housing FAQ

Is this a complete vacuum circuit breaker or vacuum interrupter?

No. It is a copper conductive component for a larger assembly, not a complete breaker, insulating enclosure or vacuum interrupter. Its position and function must be confirmed from the equipment drawing.

Can it connect to a moving contact or flexible copper shunt?

The design can be reviewed for those interfaces. Confirm shunt attachment, available travel, window clearance, contact pressure and mechanical loading. The opening alone does not establish compatibility with a particular breaker model.

Is the body forged or cast?

The production route is confirmed with the order, not identified from surface texture alone. Wrought or forged blanks can be reviewed for machining; a casting route requires its own approved material grade, process and internal-quality requirements.

Which copper grade should be specified?

C11000, C10200 and C10100 can be reviewed for wrought routes against conductivity, material condition and joining requirements. C18150 is a separate higher-strength alloy option, not an interchangeable pure-copper grade; any substitution needs engineering approval.

Can the window and mounting-hole patterns be changed?

Yes, subject to manufacturability review. Provide window dimensions, corner radii, hole locations, thread sizes and engagement depths. Identify contact faces and datums, and state whether critical dimensions apply before or after plating.

Does the rounded profile guarantee a current rating or corona-free performance?

No. Current capacity and temperature rise depend on the complete current path, contacts and cooling. Dielectric and corona performance also depend on insulation, clearances and electric-field distribution. Equipment-level requirements need defined validation.

Can the contact faces be silver-plated?

Full or selective silver plating can be reviewed, with tin or nickel where specified. Define coating thickness, undercoat, masking and acceptance criteria. Thread fits, step dimensions and mating clearances must account for the coating.

What inspection documents can be supplied?

Material certificates, dimensional reports and coating records can be agreed with the order. Conductivity and internal-soundness tests need specified methods, coverage and acceptance limits. EN 10204 Type 3.1 documentation and third-party inspection require advance confirmation.

Request a Quote

Contact Cymber Metalwith your 2D/3D drawing, copper grade and condition, quantity, window and mounting details, contact-face requirements, plating specification, inspection documents, destination and required delivery date. Include operating current, duty cycle, equipment voltage and mechanical loading where relevant.