Custom 3D-Bent Copper Tubular Busbar
Video
Short Description
Custom copper tubular busbar combining a spatially bent body, a stepped cylindrical connection end and a two-hole flat terminal palm. The round-to-flat configuration provides a transition between cylindrical interfaces and bolted flat connections. Material grade, bend geometry, terminal dimensions, surface treatment and inspection requirements are specified by drawing for switchgear, transformer and industrial electrical projects.
Product Overview
A copper tubular busbaris an electrical conductor with a hollow tubular body. In this round-to-flat design, the bent body routes the conductor around surrounding equipment, while the flat terminal palm provides a bolted connection interface.
The photographed component shows a stepped cylindrical end, multiple bends and a flat terminal with two mounting holes. Bore dimensions, wall thickness, material grade and manufacturing route require drawing or production-record confirmation.
Cymber Metal can support material selection through itspure copper product rangeand drawing-based interface development through itscopper machining support. Final design review should consider terminal alignment, assembly access, contact pressure, temperature rise and electrical insulation requirements.
Key Features
| Feature | Design Purpose / Buyer Consideration |
|---|---|
| Round-to-Flat Transition | Connects a tubular conductor body to a flat bolted interface |
| Spatially Bent Body | Accommodates drawing-defined routing and terminal offsets |
| Stepped Cylindrical End | Provides a defined mating diameter where required by the assembly |
| Two-Hole Terminal Palm | Provides two fastening locations; rotational restraint depends on the complete joint design |
| Defined Contact Surface | Allows flatness, roughness and plating requirements to be specified |
| Custom Terminal Orientation | Aligns the round and flat interfaces with the mating equipment |
| Selective Finishing | Allows contact zones and non-contact areas to receive different treatments when specified |
Silver, tin or nickel finishing can be reviewed through Cymber Metal’sbusbar plating support. Coating thickness, coverage, adhesion and dimensional allowance must be defined for the order.
Manufacturing Process
The production route should be agreed after reviewing the material, tube section, bends and terminal design.
| Stage | Process Considerations |
|---|---|
| Drawing and Material Review | Confirm grade, temper, tube dimensions, terminal datums and functional requirements |
| Blank Preparation | Prepare the specified tube stock and cutting allowance |
| Conditioning and Bending | Review annealing needs and bending method to control springback, ovality and wall thinning |
| Round-to-Flat End Forming | Develop the palm transition with controlled thickness, width and bend geometry |
| Interface Machining | Finish specified diameters, contact faces, holes and edge details using suitable fixtures |
| Surface Treatment | Apply the agreed cleaning, plating or insulation process |
| Final Inspection and Packing | Verify drawing requirements and protect contact surfaces during shipment |
An integral flattened-tube design must be distinguished from a separately joined terminal. Flattening alone does not establish metallurgical bonding between the opposing tube walls.
Manufacturing & Quality Control
Inspection methods, sampling frequency and acceptance limits should form part of the agreed inspection plan.
| Control Area | Inspection / Verification |
|---|---|
| Material Identity | Review material certificates and perform supplementary verification when specified |
| Oxygen-Free Grade Requirements | Confirm oxygen-related requirements using appropriate certification or testing; appearance is not proof |
| Tube Section | Check outside diameter, wall thickness and accessible bore dimensions |
| Bend Quality | Evaluate bend radius, ovality, wall thinning and visible surface defects |
| Spatial Geometry | Measure terminal positions and orientation against agreed datums |
| Palm and Mounting Holes | Check palm thickness, hole diameter, spacing, edge distance and terminal angle |
| Contact Surfaces | Verify specified flatness, roughness and surface condition |
| Formed-Zone Integrity | Use visual inspection and, where technically suitable and agreed, additional nondestructive testing |
| Electrical Properties | Perform conductivity or resistance testing when required by the order |
| Coating and Documentation | Verify specified coating requirements and supply the agreed inspection records |
Cymber Metal’squality certification informationcan support supplier-document review. Current certificates, EN 10204 3.1 documentation where applicable, and special inspection reports should be confirmed before ordering.
Typical Applications
These are potential application contexts, not automatic equipment approvals or voltage ratings.
| Application | Typical Connection Role | Design Checks |
|---|---|---|
| Switchgear and Ring Main Units | Shaped internal connection between offset terminals | Temperature rise, assembly access, insulation clearances and fault-current forces |
| Gas-Insulated Equipment | Drawing-specific round-to-flat internal conductor | Electric-field design, dielectric performance, partial discharge and equipment qualification |
| Transformer Connections | Transition between cylindrical and flat terminal interfaces | Contact pressure, mechanical support, thermal loading and terminal alignment |
| Inverters and Industrial Power Electronics | Spatially routed electrical link within an enclosure | Current waveform, frequency, temperature, insulation and fastening requirements |
| Induction Heating Equipment | Custom electrical connection between power components | Duty cycle, current distribution and cooling arrangements; no pressure rating implied |
Frequently Asked Questions
A copper tubular busbar is an electrical conductor with a hollow tube section. This version combines a bent body with cylindrical and flat connection interfaces. Its current-carrying capability depends on the conducting cross-section, material, operating frequency, cooling conditions, joint design and permitted temperature rise.
A tubular busbar has a hollow section, while a solid busbar has a fully filled cross-section. Neither is automatically superior. Selection should consider available space, electrical loading, mechanical support, forming requirements and connection geometry. The tube’s external diameter alone does not establish its electrical capacity.
C11000, C10200 and C10100 can be reviewed against the project requirements. Selection should account for conductivity, forming operations, joining conditions and documentation needs. The required grade, standard and temper must be stated explicitly; designations from different standards should not be assumed equivalent without checking their requirements.
Drawing-defined bend radii, offsets, terminal angles, stepped diameters and hole patterns can be reviewed. Feasibility depends on tube diameter, wall thickness, material condition, tooling access and inspection requirements. A 3D model together with a dimensioned 2D drawing helps define both the routing envelope and critical connection interfaces.
No. The construction must be confirmed from the approved manufacturing route. An integral formed-tube design differs from a tube fitted with a separately welded or brazed terminal. Photographs alone cannot verify the absence of joints, internal defects or the degree of bonding within a flattened tube end.
Silver, tin or nickel plating and selected insulation treatments can be reviewed for the project. Specify the treatment areas, coating thickness, masking boundaries and inspection requirements. Insulation thickness or material alone does not establish a complete assembly’s voltage rating, creepage distance or clearance compliance.
No fixed rating should be assigned from these photographs or reference dimensions. Current capacity requires thermal evaluation, while voltage suitability depends on the complete insulation and equipment design. High-voltage applications may also require electric-field analysis, partial-discharge assessment and equipment-level testing.
Provide the material specification, drawings, quantity, tube dimensions, bend geometry, terminal interfaces, tolerances and surface treatment. Include operating current, AC/DC conditions, frequency, insulation requirements and required documents. State the delivery destination and target schedule so feasibility, inspection scope and delivery planning can be reviewed together.
Request a Quote
| Required Information | Details to Provide |
|---|---|
| Drawings | Dimensioned PDF and available STEP or other 3D model |
| Material | Grade, standard, temper and required electrical properties |
| Tube Geometry | Outside diameter, wall thickness and developed length |
| Bend Layout | Radii, angles, offsets, routing envelope and terminal orientation |
| Connection Interfaces | Stepped diameters, palm dimensions, hole pattern and mating components |
| Critical Requirements | Datums, tolerances, contact flatness and roughness |
| Operating Conditions | Current, AC/DC, frequency, temperature and installation environment |
| Surface Treatment | Plating, insulation, coverage boundaries and thickness |
| Quantity | Sample quantity, batch quantity and expected annual demand |
| Inspection Documents | Material certificate, dimensional report and any special testing |
| Delivery | Destination, packing requirements and target schedule |