Custom Insulated Copper Tubular Busbar with Threaded Ends
Video
Short Description
Custom copper tubular conductor with a red insulating layer, exposed copper end features and threaded connection ports as specified. Tube dimensions, thread details, insulation coverage and end geometry are defined by the approved drawing and mating assembly requirements.
Product Overview
This insulated copper tubular busbar has a long cylindrical body covered by a red insulating layer, with copper end sections exposed for connection. The photos show a stepped collar at one end and a female-threaded port in the close-up. The product brief describes internal threads at both ends; confirm the geometry of each port against the drawing.
This design may suit compact electrical assemblies where a formed tubular conductor and insulated central section are required. The visible color does not establish the insulation material, dielectric performance or voltage rating. Specify the copper grade, insulation system, coverage, end interfaces and required electrical tests for the application. Cymber Metal’sPure Copperrange is a starting point for discussing conductor material options.
Key Features
| Feature | Practical Value |
|---|---|
| Red Insulated Body | Separates the covered conductor surface from other components as defined by the assembly design. |
| Exposed Copper Ends | Provide accessible connection zones where specified. |
| Stepped End Collar | Offers a configurable shoulder or mating profile for the end interface. |
| Threaded Connection Ports | Accommodate specified threaded studs or mating components. |
| Tubular Conductor Form | Provides a hollow conductor profile; any fluid or gas service must be separately specified and validated. |
| Defined Insulation Cutback | Allows the exposed contact length and insulation termination to match the drawing. |
| Drawing-Based Configuration | Coordinates conductor dimensions, insulation coverage and end interfaces for the intended equipment. |
Manufacturing Process
The manufacturing and insulation route should be established after reviewing the tube specification, end features, insulation requirements and application. The photos do not determine the insulation material or production method.
| Stage | Process Scope |
|---|---|
| 1. Drawing Review | Confirm conductor dimensions, threads, collar features, insulation coverage and inspection requirements. |
| 2. Material Selection | Specify the copper grade, temper and documentation requirements. |
| 3. Tube Preparation | Prepare and cut the copper tube to the required blank dimensions. |
| 4. End Machining | Machine the specified collars, bores, counterbores and internal threads. |
| 5. Surface Preparation | Prepare the covered section and exposed contact zones according to the selected insulation process. |
| 6. Insulation Application | Apply the specified insulating layer or sleeve using the approved method. |
| 7. Insulation Trimming | Finish the insulation ends to the specified cutback and exposed contact lengths. |
| 8. Optional Contact Finish | Apply specified plating to defined bare-copper contact areas if required. |
| 9. Final Inspection | Check dimensions, threads, insulation coverage and any specified electrical tests. |
Cymber Metal’sFine Machiningservice can be considered for the end-interface machining review. If a plated finish is required, define the coating type, thickness and coverage for review with theBusbar Plating Shop.
Manufacturing & Quality Control
| Control Area | Inspection / Verification Scope |
|---|---|
| Material | Verify the copper grade and temper against the agreed purchasing documents. |
| Tube Dimensions | Inspect outside diameter, wall thickness and overall length as specified. |
| End Geometry | Check collar dimensions, exposed contact length and end-face features. |
| Internal Threads | Verify thread standard, size, pitch and fit using the agreed method. |
| Port Position | Check end alignment and position against drawing datums. |
| Insulation Coverage | Inspect covered length, cutback position and visible surface condition. |
| Insulation Testing | Apply specified thickness, continuity, withstand-voltage or partial-discharge tests only when included in the agreed inspection plan. |
| Contact Zones | Inspect exposed copper surfaces and any specified plating. |
| Documentation | Provide material and inspection records as required by the purchase specification. |
Inspection methods and acceptance criteria should be agreed before production. SeeQuality Assurancefor Cymber Metal’s quality-control approach.
Typical Applications
These are potential applications based on the product form. Final suitability depends on the equipment design and validation requirements.
| Application | Potential Role | Design Considerations |
|---|---|---|
| Switchgear Assemblies | Insulated conductor section or tubular busbar connection | Voltage class, clearances, insulation system and end interfaces |
| Gas-Insulated Switchgear | Compact internal conductor route | Equipment-specific insulation coordination and interface design |
| Ring Main Units | Insulated tubular conductor between connection points | Enclosure layout, phase spacing and terminal geometry |
| Compact Substations | Busbar connection within a constrained assembly | Insulation requirements, conductor duty and mounting arrangement |
| Power Converters | Insulated conductor or busbar segment | Current duty, temperature rise, cooling and mechanical support |
| Energy-Storage Equipment | Tubular conductor connection | System voltage, thermal conditions and validated insulation requirements |
Frequently Asked Questions
It is a copper tube conductor with an insulating layer over a specified portion of its surface. Bare copper zones may remain exposed at the ends for connection. The insulation type, coverage and electrical performance should be defined by the application specification.
The photos show a red outer layer but do not establish its material. Specify whether the design requires a sleeve, heat-shrink material, molded insulation or an applied coating, together with relevant thickness, temperature and electrical requirements.
The product brief describes threaded interfaces at both ends, and one photo clearly shows a female-threaded port. Confirm each end’s thread standard, size, pitch, tolerance class and engagement depth on the approved drawing.
Yes. Define the insulation cutback location, exposed contact length, collar dimensions and any required transition between the insulation and copper interface. These details affect assembly fit and should be shown on the drawing.
Not by itself. Suitability depends on the insulation material, thickness, geometry, environmental conditions and the complete assembly’s electrical validation. Specify the required voltage and test criteria rather than inferring a rating from color or appearance.
Selective plating can be reviewed when specified. Identify the plating type, thickness and areas to be plated. Also define any masking requirements and account for coating buildup at threaded or mating interfaces.
The photos and brief identify a tubular conductor, but they do not confirm pressure capability or suitability for coolant service. If fluid service is intended, specify the medium, pressure, flow, sealing method and leak-test requirements for separate review.
Provide a dimensioned drawing or 3D model, copper grade, tube dimensions, thread details, insulation material and coverage, quantity, tolerances, finish and inspection requirements. Include the equipment application and any required electrical tests.
RFQ Information
| Required Information | Details to Provide |
|---|---|
| Drawing | Dimensioned PDF and STEP or another suitable 3D format |
| Copper Material | Grade, standard, temper and required documentation |
| Quantity | Prototype quantity, order quantity and expected annual demand |
| Tube Dimensions | Outside diameter, wall thickness and overall length |
| End Features | Collar dimensions, threads, bores and mating-component details |
| Thread Details | Standard, size, pitch, tolerance class and engagement depth |
| Insulation | Material, method, thickness, covered length and cutback positions |
| Electrical Requirements | Application voltage, clearances and required validation tests |
| Surface Finish | Bare copper or specified plating, thickness and coverage |
| Inspection | Dimensional checks and any specified insulation or leak tests |
| Delivery | Destination, packaging requirements and target schedule |
Send the drawing and requirements throughContact Usfor material and manufacturing review.









